Siemens 5SY7340-7 — Miniature Circuit Breakers (MCB)

Siemens 5SY7340-7 SENTRON MCB, 3P C-Curve, 15/20 kA

MPN5SY7340-7
Active

Siemens SENTRON 5SY7340-7, 3-pole miniature circuit breaker, C-curve, 400 V AC, 15 kA (EN 60898-1) / 20 kA (IEC 60947-2), 50/60 Hz.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY7340-7 — Ratings
ParameterValue
Overvoltage categoryIII
5SY7340-7 — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

SENTRON 5SY7340-7 — 3-pole C-curve MCB for panel and machine builds

The Siemens SENTRON 5SY7340-7 is a 3-pole miniature circuit breaker with C-curve tripping characteristic, designed for 400 V AC operation at 50/60 Hz. It carries a dual-rated breaking capacity: 15 kA per EN 60898-1 and 20 kA per IEC 60947-2, with a DC rating of 15 kA at 60 V per IEC 60947-2. At 3 modular width units (54 mm wide, 76 mm deep, 90 mm tall), it occupies the same footprint as a standard 3P MCB — no panel rework needed when replacing an existing unit. The IP20 rating applies with conductors connected, which is the normal installed state inside an enclosure.

Breaking capacity and selectivity — what the dual rating means for coordination

The 15 kA rating under EN 60898-1 is the value used for residential and light commercial coordination per IEC 60364. The 20 kA rating under IEC 60947-2 applies when the breaker is specified for industrial duty — the higher figure reflects the standard's more demanding test sequence (including O-CO at rated service short-circuit). The DC rating of 15 kA at 60 V covers DC auxiliary circuits fed from the same bus.

Thermal derating and environmental limits

The evidence specifies a derating curve: max 95 % humidity at 55 °C, dropping to max 55 % at 70 °C and max 35 % at 75 °C. In a sealed panel with multiple breakers ganged together, this derating matters — the C-curve's thermal trip element responds to ambient heat, so a tightly packed row near the top of the enclosure may nuisance-trip if the internal temperature exceeds 55 °C without applying the derating factor.

Certified to IEC / EN 60898-1 and IEC / EN 60947-2, with UL 1077 recognition for the North American market (5 kA at AC per UL 1077 / CSA C22.2 No.235). Sealable terminals are standard — allows the panel builder to lock the cover after commissioning.

Frequently asked questions

What are the key ratings of the 5SY7340-7?

It is a 3-pole C-curve MCB rated 400 V AC, 50/60 Hz, with breaking capacities of 15 kA per EN 60898-1 and 20 kA per IEC 60947-2. DC rating is 15 kA at 60 V per IEC 60947-2. Operating temperature range is -40 °C to +75 °C with derating above 55 °C.

Where can I buy the 5SY7340-7 and get current pricing?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will the 5SY7340-7 drop into a panel specified for the 5SY4140-7?

Both are 3-pole SENTRON MCBs with the same DIN-rail footprint (3 MW, 54 mm wide). The 5SY7340-7 carries a higher breaking capacity (15/20 kA vs the 5SY4140-7's 10 kA typical for the 40 A variant). No rewiring is needed if the panel's SCCR rating accommodates the higher let-through of the 5SY7340-7 — verify the upstream coordination study.

What compliance documentation does Siemens provide for the 5SY7340-7?

The breaker is certified to IEC / EN 60898-1, IEC / EN 60947-2, and UL 1077 / CSA C22.2 No.235. It is halogen-free and silicon-free. Standard documentation includes the declaration of conformity and the UL recognition file.

MPN
5SY7340-7