Skip to main content
Siemens 5SY7363-6 — Miniature Circuit Breakers (MCB)

Siemens 5SY7363-6 SENTRON MCB, 63 A, 3-Pole, Char B, 15/20 k

MPN5SY7363-6
Active

Siemens SENTRON 5SY7363-6, miniature circuit breaker, 3-pole, 63 A, tripping characteristic B, 15 kA (EN 60898) / 20 kA (IEC 60947-2), IP20, 3 MW units.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY7363-6 — Ratings
ParameterValue
Overvoltage categoryIII
5SY7363-6 — Mechanical
ParameterValue
Width54 mm
Height90 mm
Depth76 mm

Product details

The Siemens SENTRON 5SY7363-6 is a 3-pole miniature circuit breaker rated 63 A with tripping characteristic B, built for AC branch-circuit protection in industrial control panels. Breaking capacity is 15 kA per EN 60898 and 20 kA per IEC 60947-2 — the IEC figure governs when used in industrial distribution with higher prospective fault current. Characteristic B trips between 3 and 5 times rated current, so it is sized for resistive or lightly inductive loads where inrush stays moderate — lighting banks, small transformers, control circuits.

Mounts on DIN rail via the quick-assembly system in any position. Occupies 3 modular width units (54 mm wide). Depth is 76 mm with 70 mm installation depth behind the panel surface — confirm clearance before laying out a shallow enclosure. IP20 with connected conductors; pollution degree 3 and overvoltage category III suit it for fixed-installation panels in factory environments. Sealable design allows lockout-tagout on the breaker handle.

Rated current derates with ambient temperature: 63 A at 35 °C, 59.98 A at 40 °C, 58.4 A at 45 °C, 56.83 A at 50 °C, 55.12 A at 55 °C, 53.42 A at 60 °C. If the panel ambient runs above 40 °C, size the upstream protection for the derated value. Halogen-free and silicon-free construction — no outgassing concerns in clean-room or electronics-adjacent installations. Combined terminals top and bottom accept standard copper conductors.

Frequently asked questions

How do I get current pricing and availability for 5SY7363-6?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is 5SY7363-6's breaking capacity?

15 kA per EN 60898 and 20 kA per IEC 60947-2. The IEC figure is the one that matters for industrial panel SCCR coordination.

What compliance documentation does this brand provide for 5SY7363-6?

The brand is Siemens SENTRON. The evidence records halogen-free and silicon-free construction; typical compliance documentation includes CE, RoHS, and REACH declarations. Specific certificates should be confirmed at order.

MPN
5SY7363-6