5SY7363-7CC SENTRON MCB, 3P, 63 A, C-Curve, 20 kA

MPN5SY7363-7CC

SENTRON miniature circuit breaker, 3-pole, 63 A, C characteristic, 20 kA (IEC 60947-2), 440 V AC, 50/60 Hz, IP20.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

5SY7363-7CC — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry

Protection

5SY7363-7CC — Protection
ParameterValue
Tripping characteristic (curve)C
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree3

Electrical

5SY7363-7CC — Electrical
ParameterValue
Rated current (AC)63 A
Rated voltage (AC, multi-phase)440 V
Neutral conductor switchingNo

Mechanical

5SY7363-7CC — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes

Environmental

5SY7363-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

What it is and what it does

The SENTRON 5SY7363-7CC is a 3-pole miniature circuit breaker rated 63 A at 40 °C with a C tripping characteristic, designed for AC distribution at 50/60 Hz up to 440 V (multi-phase). Its 20 kA breaking capacity per IEC 60947-2 means it can safely interrupt fault currents up to that level without upstream cascading — a key spec for panel coordination studies. Rated for overvoltage category III and pollution degree 3, it suits industrial control panels and main distribution boards where transient overvoltages and conductive dust are present. The C-curve (5–10× In magnetic trip) handles moderate inrush from motor starters and transformer banks without nuisance tripping.

Mounting and integration

Snaps onto DIN rail via the quick assembly system; 3 modular width units (54 mm) at 76 mm depth. Any mounting position is allowed, and the combined top/bottom terminals accept both feed-through and loop-through wiring without extra accessories. Sealable enclosure, halogen-free and silicon-free construction — relevant for clean-room or food-production environments where outgassing contaminants are a concern. IP20 with connected conductors; install inside a rated enclosure for washdown areas.

Thermal derating and real-world current

The 63 A rating holds at 35 °C ambient. At 40 °C it derates to 59.54 A, at 45 °C to 57.71 A, at 50 °C to 55.82 A, and at 55 °C to 53.86 A. If your panel internal ambient runs above 35 °C, size the upstream protection or load accordingly — the nameplate 63 A is not the continuous rating at elevated temperature.

Frequently asked questions

What is the breaking capacity of 5SY7363-7CC?

20 kA per IEC 60947-2 at 440 V AC multi-phase. That rating governs the maximum fault current the breaker can safely interrupt without welding or arc-over.

Will 5SY7363-7CC drop into a panel specified for 5SY7210-7CC?

Both are SENTRON 3-pole MCBs on the same DIN-rail footprint with identical width (54 mm) and depth (76 mm). The 5SY7363-7CC is rated 63 A / 20 kA; the 5SY7210-7CC is a lower-current variant. Mechanically interchangeable, but verify the load current and fault level match the 5SY7363-7CC's higher ratings before substitution.

Where can I buy 5SY7363-7CC and how is it quoted?

Sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead-time commitment.