Siemens 5SY7402-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY7402-7 SENTRON MCB, 4P C-Curve 2A 400V AC

MPN5SY7402-7
Active

Siemens SENTRON 5SY7402-7, 4-pole miniature circuit breaker, C-curve, 2 A rated at 400 V AC, 15 kA breaking capacity per EN 60898, 50 kA per IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7402-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY7402-7 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY7402-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 6089815 kA
Rated breaking capacity, per IEC 60947-250 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY7402-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY7402-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

The Siemens 5SY7402-7 is a SENTRON 4-pole miniature circuit breaker with a C-curve trip characteristic, rated 2 A at 400 V AC. It carries a 15 kA breaking capacity per EN 60898 and 50 kA per IEC 60947-2, giving it headroom for high-fault installations like industrial panel feeders or distribution sub-mains.

The 15 kA rating under EN 60898 covers the standard domestic/commercial fault level; the 50 kA under IEC 60947-2 addresses industrial installations where the prospective short-circuit current at the panel is higher. That dual rating means the same MCB satisfies both a building-services spec and a machine-control cabinet spec without swapping parts.

Snaps onto DIN rail via the quick assembly system; 4 modular width units (72 mm wide) occupy four 18 mm slots. Mounting position is unrestricted, so it can be installed vertically, horizontally, or flat in a panel without derating the 2 A rating.

Thermal derating and environment

Rated 2 A at 35 °C ambient; derates to 1.9 A at 40 °C, 1.85 A at 45 °C, 1.8 A at 50 °C, 1.75 A at 55 °C, and 1.7 A at 60 °C.

Frequently asked questions

What is the breaking capacity of the 5SY7402-7?

15 kA per EN 60898 and 50 kA per IEC 60947-2 at 400 V AC.

What is the 5SY7402-7 used for?

It is a 4-pole C-curve miniature circuit breaker rated 2 A at 400 V AC, used for overcurrent and short-circuit protection in industrial panels, distribution sub-mains, and mechanical engineering applications.

Where can I buy the 5SY7402-7?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the width of the 5SY7402-7?

72 mm, which corresponds to 4 modular width units on a DIN rail.

Does the 5SY7402-7 drop into a panel specified around the 5SY4304-7CV?

Both are 4-pole SENTRON MCBs on the same DIN-rail footprint, so physical fit is the same. The 5SY7402-7 is a C-curve 2 A unit; the 5SY4304-7CV is a different rating and curve — verify the trip characteristic and ampacity against the circuit design before substituting.