Skip to main content
Siemens 5SY7402-8CC — 4-Pole MCB (DIN Rail)

Siemens 5SY7402-8CC SENTRON MCB, 4P, D Curve, 2 A, 50 kA

MPN5SY7402-8CC

Siemens SENTRON, miniature circuit breaker, 5SY7402-8CC, 4-pole, D tripping characteristic, rated current 2 A at 440 V AC, breaking capacity 50 kA per IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7402-8CC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY7402-8CC — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC2 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
5SY7402-8CC — Protection
ParameterValue
Tripping characteristic (trip curve)D
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SY7402-8CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY7402-8CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY7402-8CC — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SY7402-8CC is a SENTRON miniature circuit breaker (MCB) with a D tripping characteristic, 4 poles, and a rated current of 2 A at 440 V AC.

Mounts in any position, with an installation depth of 70 mm and overall depth of 76 mm — fits standard 80 mm deep enclosures without the gland plate interfering.

At 2 A, this is sized for a small motor or control transformer branch circuit. Temperature derating is published: at 40 °C it carries 1.89 A, at 50 °C it carries 1.77 A — so if the panel ambient runs hot, factor that into the load calculation.

Frequently asked questions

What is the breaking capacity of the 5SY7402-8CC?

50 kA per IEC 60947-2 at 440 V AC, which is the standard for industrial-grade MCBs in high-fault panels.

What does the D tripping characteristic mean for this breaker?

The D curve allows magnetic trip at 10–14× rated current, so it handles motor and transformer inrush without nuisance tripping.

Where can I buy the 5SY7402-8CC?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

MPN