Skip to main content
Siemens 5SY7406-6 — 4-Pole MCB (DIN Rail)

Siemens 5SY7406-6 SENTRON MCB, 4P, 6A, B Curve, 15/40 kA

MPN5SY7406-6
Active

Siemens SENTRON 5SY7 series miniature circuit breaker, 4-pole, 6 A, B tripping characteristic, 15 kA (EN 60898) / 40 kA (IEC 60947-2), 400 V AC, 72 V DC max, IP20, halogen-free, silicon-free.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7406-6 — Identification
ParameterValue
Type / order code5SY7
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY7406-6 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated current (In), AC6 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY7406-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 6089815 kA
Rated breaking capacity, per IEC 60947-240 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY7406-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY7406-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY7406-6 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SY7406-6 is a 4-pole miniature circuit breaker from the SENTRON 5SY7 family, rated 6 A at 400 V AC with a B tripping characteristic — meaning it trips between 3 and 5 times rated current, suited for resistive and light inductive loads where inrush is modest. It carries a 15 kA breaking capacity under EN 60898 and 40 kA under IEC 60947-2, so it can handle high prospective fault currents in industrial panels without cascading upstream. The DC rating maxes out at 72 V, useful for control circuits or battery-backed loads in the same enclosure.

Frequently asked questions

Where can I buy 5SY7406-6?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quote.

What conductor sizes does 5SY7406-6 accept?

The terminals accept solid and stranded conductors from 0.75 mm² up to 35 mm², covering most branch-circuit wiring sizes without adapters.

What is the breaking capacity of 5SY7406-6?

It is rated 15 kA under EN 60898 and 40 kA under IEC 60947-2 at 400 V AC, giving headroom for high-fault installations.

Will 5SY7406-6 drop into a panel specified around 5SY7140-8CC without rewiring?

Both are 4-pole SENTRON MCBs with the same DIN-rail footprint and terminal range, so mechanical fit is identical. However, 5SY7140-8CC is a 40 A C-curve device — the 6 A B-curve of 5SY7406-6 is a different rating and characteristic, so the branch circuit must be re-evaluated for load and coordination.

MPN
5SY7406-6