Siemens 5SY7406-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY7406-7 SENTRON MCB, 4P C-Curve 6A, 15/40 kA

MPN5SY7406-7
Active

Siemens SENTRON 5SY7406-7, 4-pole miniature circuit breaker, C-curve, 6 A rated, 15 kA (EN 60898) / 40 kA (IEC 60947-2), 72 mm wide, 76 mm deep.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY7406-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY7406-7 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SY7406-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY7406-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY7406-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY7406-7 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.6 W

Product details

The 5SY7406-7: Breaking capacity is 15 kA per EN 60898 and 40 kA per IEC 60947-2 — the IEC figure governs fault interruption in industrial control panels where the prospective short-circuit current can exceed the residential EN rating.

Derating and thermal limits

At 35 °C ambient the breaker holds its full 6 A rating. Above that, derate linearly: 5.71 A at 40 °C, 5.56 A at 45 °C, 5.41 A at 50 °C, 5.25 A at 55 °C, and 5.09 A at 60 °C. If the panel internal temperature runs hot — common in sealed enclosures — factor the 40 °C or 50 °C column into the load calculation, not the 35 °C figure. Operating temperature range spans -40 °C to +75 °C, with humidity limits of 95 % up to 55 °C, 55 % to 70 °C, and 35 % to 75 °C. The storage range exceeds the operating range — that governs handling, not running.

Occupies four standard 18 mm DIN slots — confirm the rail allocation before committing the BOM if the panel is already dense. Sealable, halogen-free, silicon-free construction.

Frequently asked questions

What is the breaking capacity of 5SY7406-7?

15 kA per EN 60898 and 40 kA per IEC 60947-2. The higher IEC figure applies in industrial distribution where fault currents are larger; the EN figure covers residential and light commercial installations.

Will 5SY7406-7 drop into a panel specified around 5SY4106-7CV without rewiring?

Both are 4-pole SENTRON MCBs with the same 72 mm width (4 MW) and quick-assembly DIN-rail mount, so the mechanical fit is identical. The 5SY7406-7 carries a C-curve at 6 A; the 5SY4106-7CV is also C-curve but at 6 A — check the trip characteristic and breaking capacity match your branch circuit requirements before swapping. No rewiring needed if the terminal positions align.

What compliance documentation is available for 5SY7406-7?

The part is designed to EN 60898 and IEC 60947-2. It carries overvoltage category III and pollution degree 3 ratings. For specific RoHS, REACH, or UL documentation, request the manufacturer's declaration of compliance with the RFQ — those are provided at order confirmation.

Where can I buy 5SY7406-7 and how is it quoted?