Siemens 5SY7406-7CC SENTRON MCB, 4P C-Curve 6A, 30kA

MPN5SY7406-7CC

Siemens SENTRON 5SY7406-7CC, miniature circuit breaker, 4-pole, C tripping characteristic, 6 A rated current, 30 kA breaking capacity per IEC 60947-2 at 400 V AC, 4 MW width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7406-7CC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY7406-7CC — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC6 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
5SY7406-7CC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY7406-7CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY7406-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY7406-7CC — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

SENTRON 5SY7406-7CC — 4-pole C-curve MCB, 6 A, 30 kA

The Siemens 5SY7406-7CC is a SENTRON miniature circuit breaker with a 4-pole design and C tripping characteristic, rated 6 A at 35 °C and 400 V AC multi-phase.

Thermal derating and ambient limits

Rated 6 A at 35 °C, the 5SY7406-7CC derates to 5.67 A at 40 °C, 5.5 A at 45 °C, 5.32 A at 50 °C, and 5.13 A at 55 °C. This means a panel running at 50 °C ambient loses roughly 11 % of the nominal rating — factor that into the load schedule if the breaker sits near heat sources or in a sealed enclosure. Operating range spans -40 °C to 75 °C, with humidity limits of 95 % up to 55 °C, 55 % up to 70 °C, and 35 % at 75 °C.

IP20 with connected conductors; sealable for tamper-proof installations. Halogen-free and silicon-free construction.

Frequently asked questions

Where can I buy 5SY7406-7CC and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at quote time.

What is 5SY7406-7CC's breaking capacity?

Rated 30 kA per IEC 60947-2 at 400 V AC, which covers most industrial panel fault-current levels up to that threshold without requiring an upstream current-limiting device.

What compliance documentation does Siemens provide for 5SY7406-7CC?

The part carries IEC 60947-2 certification and is classified per EN 61346-2 and IEC 81346-2 as function F. It is halogen-free and silicon-free. Specific RoHS/REACH/UL declarations are available from the manufacturer's documentation portal for this SENTRON series.

MPN