Siemens 5SY7406-8MA — 4-Pole MCB (DIN Rail)

Siemens SENTRON 5SY7406-8MA MCB, 4P, 6 A, D-curve, 30 kA

MPN5SY7406-8MA

Siemens SENTRON 5SY7406-8MA miniature circuit breaker, 4-pole, 6 A, D tripping characteristic, 30 kA breaking capacity at 400 V AC per IEC 60947-2, IP20, quick-assembly mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7406-8MA — Identification
ParameterValue
Type / order code5SY7MA
Brand nameSENTRON
Application suitabilityIndustry
5SY7406-8MA — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated current (In), AC6 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY7406-8MA — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity, per IEC 60947-230 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY7406-8MA — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY7406-8MA — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY7406-8MA — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The D-curve means it tolerates short-duration surges up to 10–20 times rated current before tripping — exactly what a motor starting or a transformer energisation pulls. The part is magnetically only — no thermal bimetal — so it trips purely on overcurrent, not overload, which suits circuits where the load itself is thermally protected downstream.

Accepts solid or stranded conductors from 0.75 to 35 mm²; screw terminals with a tightening torque of 2.5 to 3.5 N·m. Combined terminal top and bottom means you can feed from either direction without flipping the breaker.

Touch protection is built in. The product designation follows DIN EN 61346-2 and DIN EN 81346-2 (function code F).

Frequently asked questions

Where can I buy 5SY7406-8MA?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What does the D tripping characteristic mean for this breaker?

The D-curve allows short-duration surges of 10–20 times the 6 A rated current before tripping, so it handles motor starting and transformer inrush without nuisance trips.

What is the breaking capacity of 5SY7406-8MA?

30 kA at 400 V AC per IEC 60947-2 — sufficient for most industrial distribution boards with high fault-current capability.

What conductor sizes does 5SY7406-8MA accept?

Solid and stranded conductors from 0.75 to 35 mm², terminated with screw terminals torqued to 2.5–3.5 N·m.