Skip to main content
Siemens 5SY7410-7CC — 4-Pole MCB (DIN Rail)

Siemens 5SY7410-7CC SENTRON MCB, 4P C-Curve 10 A, 25 kA IEC

MPN5SY7410-7CC

Siemens SENTRON 5SY7410-7CC, 4-pole miniature circuit breaker, C-trip curve, 10 A rated current, 25 kA breaking capacity at 400 V AC per IEC 60947-2, 5 kA per UL 1077.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7410-7CC — Identification
ParameterValue
Type / order code5SY7CC
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY7410-7CC — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated current (In), AC10 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY7410-7CC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity, per IEC 60947-225 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY7410-7CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY7410-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY7410-7CC — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

SENTRON 5SY7410-7CC — 4-pole C-curve MCB for panel and machine builds

It breaks 25 kA at 400 V AC per IEC 60947-2, and 5 kA per UL 1077 and CSA C22.2 No. 235 — enough headroom for most industrial panel secondary circuits and machine control cabinets. For a 10 A breaker, that means the magnetic trip fires between 50 A and 100 A — fast enough to clear a hard short, tolerant enough to ride through a brief inrush. Rated for 400 V AC phase-to-phase (440 V single- or multi-phase), with a max DC rating of 72 V — so it covers standard 400 V three-phase panels and some lower-voltage DC branches, but not a 125 V DC bus.

Mounting position any, so it fits horizontal or vertical busbars without derating. IP20 with conductors connected — fine for enclosed panels, not for open washdown zones. Sealable cover is standard, which matters for panel builders who lock out circuits during maintenance.

For a fast-moving 10 A C-curve 4-pole MCB, expect standard lead times — this is a common panel spare, not a long-tail oddity.

With 25 kA IEC breaking capacity at 400 V, this breaker coordinates cleanly downstream of a larger molded-case or air circuit breaker in a typical distribution board. The 5 kA UL 1077 rating covers North American panelboard applications where the upstream device limits fault current.

Frequently asked questions

What is the breaking capacity of 5SY7410-7CC?

25 kA at 400 V AC per IEC 60947-2, and 5 kA per UL 1077 / CSA C22.2 No. 235. The 25 kA IEC rating gives solid fault-clearing headroom for industrial panel secondary circuits.

Where can I buy 5SY7410-7CC and get current pricing?

Sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote on this active-production MCB.

What compliance documentation does Siemens provide for 5SY7410-7CC?

The breaker carries IEC 60947-2 and UL 1077 / CSA C22.2 No. 235 certifications. It is halogen-free and silicon-free, and rated for overvoltage category III. Standard Siemens declarations (CE, UKCA, RoHS, REACH) apply.

MPN
5SY7410-7CC