Siemens 5SY7416-7CC — Miniature Circuit Breakers (MCB)

Siemens 5SY7416-7CC SENTRON MCB, 4P, 16 A, C-Curve, 25 kA

MPN5SY7416-7CC

Siemens SENTRON 5SY7416-7CC, 4-pole miniature circuit breaker, 16 A rated current, C tripping characteristic, 25 kA breaking capacity per IEC 60947-2, 400 V AC, 72 mm wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY7416-7CC — Ratings
ParameterValue
Overvoltage categoryIII
5SY7416-7CC — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

What it is and what it does

The Siemens 5SY7416-7CC is a 4-pole miniature circuit breaker from the SENTRON series, rated 16 A at 400 V AC with a C tripping characteristic. It's built for branch-circuit protection in industrial control panels, distribution boards, and machinery — the C curve handles moderate inrush from motor starters and transformers without nuisance trips. The 25 kA breaking capacity per IEC 60947-2 means it can clear a fault up to that level without welding contacts or cascading upstream, which is the spec that governs coordination in a panel. For UL 1077 / CSA C22.2 No. 235 installations, the interrupting rating is 5 kA — that's the number to use when the job spec calls for North American listing.

Panel fit and mounting

Snaps onto DIN rail via the quick-assembly system — no tools needed for the rail mount, but the combined terminals at top and bottom accept screwdriver termination. The 72 mm width (4 width units at 18 mm each) and 76 mm depth mean it occupies the same footprint as a standard 4-pole MCB; the 70 mm installation depth leaves room behind the panel door. Mounting position is any orientation, and the IP20 rating (with conductors connected) is typical for enclosed distribution boards — not for wet areas. The breaker is sealable, so a panel builder can lock the toggle position after commissioning.

Environmental and compliance

Rated for ambient temperatures from -40 °C to 75 °C, which covers most indoor industrial enclosures and even unheated warehouses. Halogen-free and silicon-free construction — relevant for clean-room or semiconductor-adjacent installations where outgassing matters. Humidity derating is specified: max 95% RH up to 55 °C, tapering to 35% at 75 °C. The overvoltage category III rating means it's suitable for fixed-installation distribution boards, not just downstream equipment. Mechanical endurance is 10,000 switching cycles — typical for a panel MCB that sees infrequent manual operation.

Frequently asked questions

What is the breaking capacity of 5SY7416-7CC?

25 kA per IEC 60947-2 at 400 V AC, and 5 kA per UL 1077 / CSA C22.2 No. 235.

Will 5SY7416-7CC fit in a panel designed for 5SY7140-8CC?

Yes, both are 4-pole MCBs with the same 72 mm width and DIN-rail mounting — no rewiring needed. The key difference is the 5SY7416-7CC has a 25 kA IEC breaking capacity versus the 5SY7140-8CC's 10 kA.

Where can I buy 5SY7416-7CC?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SY7416-7CC