Siemens 5SY7504-8 — 1-Pole MCB (DIN Rail)

Siemens 5SY7504-8 SENTRON MCB, D-curve, 4A, 2-pole, 15kA

MPN5SY7504-8
Active

Siemens SENTRON 5SY7 series, miniature circuit breaker, order code 5SY7504-8, D tripping characteristic, 4 A rated current, 2-pole (1P+N), 15 kA breaking capacity per EN 60898, 40 kA per IEC 60947-2, 36 mm width, 76 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY7504-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityMechanical engineering / industry
5SY7504-8 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Rated value (EN 60898)15 kA
Overvoltage categoryIII
5SY7504-8 — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY7504-8 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY7504-8 is a SENTRON miniature circuit breaker from the 5SY7 series, designed for branch-circuit protection in industrial control panels. It carries a D tripping characteristic — meaning it tolerates the high inrush currents typical of motor and transformer loads before tripping — and is rated 4 A at 230 V AC. The 2-pole (1P+N) configuration switches both phase and neutral, with the neutral pole switching confirmed by the product function.

Breaking capacity and selectivity

The 5SY7504-8 is rated 15 kA per EN 60898 and 40 kA per IEC 60947-2 — the higher figure under the industrial standard gives headroom for high-fault installations. For UL 1077 / CSA C22.2 No. 235 the rating is 5 kA, which governs North American panel acceptance. The 40 kA SCCR under IEC 60947-2 means this breaker can safely interrupt faults up to that level without cascading upstream, a key figure for selectivity studies in a distribution board.

Mounting and panel integration

Snap-on mounting to DIN rail via the quick assembly system; any mounting position is permitted. The 36 mm width occupies 2 width units on the rail. Installation depth is 70 mm; overall depth with terminals is 76 mm. The combined top and bottom terminals accept wiring from either direction, and the neutral conductor is switched internally — no separate neutral bar needed for the switched pole. IP20 with connected conductors, pollution degree 3, overvoltage category III.

Environmental and material specs

Rated for ambient temperatures from -40 °C to 75 °C, with humidity influence capped at 95% up to 55 °C, derating to 35% at 75 °C. Halogen-free and silicon-free construction. Sealable for tamper-evident installations. Touch protection is built in.