Siemens 5SY7563-8 — 1-Pole MCB (DIN Rail)

Siemens 5SY7563-8 SENTRON MCB, 63A D Curve, 2-Pole, 15kA

MPN5SY7563-8
Active

Siemens SENTRON 5SY7 series miniature circuit breaker, order code 5SY7563-8, 2-pole 1P+N, 63 A rated current at 230 V AC, D tripping characteristic, 15 kA breaking capacity per IEC 60898.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY7563-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Application suitabilityMechanical engineering / industry
5SY7563-8 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Rated value (EN 60898)15 kA
Overvoltage categoryIII
5SY7563-8 — Mounting & Connection
ParameterValue
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
SealableYes
5SY7563-8 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Halogen-freeYes
Silicone-freeYes

Product details

63 A D-curve MCB for high-inrush loads

The Siemens 5SY7563-8 is a SENTRON miniature circuit breaker rated 63 A at 230 V AC with a D tripping characteristic, meaning it tolerates the high inrush currents typical of motor starters, transformers, and discharge lighting without nuisance trips — the magnetic trip threshold sits at 10–20× rated current, so it passes the start-up spike and clears only on a hard fault. Breaking capacity is 15 kA per IEC 60898 and IEC 60947-2, with a separate 5 kA rating under UL 1077 and CSA C22.2 No.235 — the UL figure governs installations in North American control panels where the available fault current stays under 5 kA; the 15 kA IEC figure applies in European distribution boards. Two-pole 1P+N configuration switches both line and neutral, with the neutral pole switching but not protecting — the overcurrent trip acts only on the phase conductor. Rated for overvoltage category III, so it's suited for fixed-installation downstream of the utility meter.

Width is 36 mm (2 width units), depth 76 mm, height 90 mm — snaps onto standard 35 mm DIN rail via the quick-assembly system. Installation depth 70 mm leaves clearance behind the rail for wiring. Mounting position any, so vertical or horizontal orientation in the panel is fine. IP20 with conductors connected — open-front protection only; keep live terminals behind a panel door or cover. Sealable enclosure option and touch protection built in. Halogen-free and silicon-free construction, so it won't outgas corrosive compounds in sealed enclosures or near sensitive electronics.

Ambient temperature range -40 to +70 °C, with humidity derating above 55 °C: max 95% RH up to 55 °C, then 55% RH at 70 °C, then 35% RH at 75 °C. Storage range -40 to +75 °C covers warehouse and transport extremes. Functional letter per DIN EN 61346-2 and DIN EN 81346-2 is F — protective device. Suitable for mechanical engineering and industry applications per the manufacturer's classification.

Frequently asked questions

What is the breaking capacity of 5SY7563-8?

15 kA per IEC 60898 and IEC 60947-2 at 230 V AC, and 5 kA per UL 1077 and CSA C22.2 No.235.

What conductor sizes does 5SY7563-8 accept?

Solid and stranded conductors from 0.75 mm² up to 35 mm², with combined top and bottom terminals for through-wiring.