Siemens 5SY7602-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY7602-7 SENTRON MCB, 4P C-Char, 15/50 kA

MPN5SY7602-7
Active

Siemens SENTRON 5SY7602-7, 4-pole (3P+N) miniature circuit breaker, C characteristic, 15 kA per EN 60898 / 50 kA per IEC 60947-2, 400 V AC, 4 MW.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7602-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY7602-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SY7602-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY7602-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY7602-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY7602-7 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.2 W

Product details

The Siemens 5SY7602-7 is a SENTRON 4-pole miniature circuit breaker wired as 3P+N, meaning it switches three phases and the neutral conductor together. That neutral switching is the key difference from a standard 3-pole unit — you get full isolation on TN-S or TN-C-S systems without a separate disconnect. The UL 1077 / CSA listing at 5 kA confirms it is accepted as a supplementary protector in North American panels — not a branch-circuit rated device under UL 489, so verify the application if you are specifying for a US service entrance. Rated AC operating voltage is 400 V, with a maximum of 440 V in single- or multi-phase operation. DC rating is 60 V per pole, maximum 72 V, with a DC breaking capacity of 15 kA per IEC 60947-2. That DC capability is unusual for a DIN-rail MCB of this width — useful if you are protecting a DC bus or battery string in the same enclosure.

Occupies 4 modular width units on standard DIN rail. Width is 72 mm, height 90 mm. IP20 with connected conductors is the standard protected-inside-the-panel rating; no special gasketing for washdown zones. The sealable cover lets you lock the toggle position after commissioning, which satisfies some machine-safety isolation requirements without a separate lockout hasp.

Humidity influence is specified per: max 95% RH at 55 °C, derating to 35% RH at 75 °C. Halogen-free and silicon-free construction avoids corrosive off-gassing in sealed cabinets with sensitive electronics. Standards compliance covers IEC / EN 60898-1, IEC / EN 60947-2, and UL 1077. Energy limitation class 3 means the let-through energy is low enough to protect downstream components under short-circuit conditions. Lifecycle stage is current production. This is not a phase-out or NRND line — the 5SY7 series remains the standard SENTRON MCB for 4-pole applications.

Frequently asked questions

Will 5SY7602-7 drop into a panel that was specified around 5SY4304-7CV without rewiring?

The 5SY7602-7 is a 4-pole (3P+N) breaker with neutral switching, while the 5SY4304-7CV is a 4-pole (4P) unit without dedicated neutral switching. Both occupy 4 modular width units on DIN rail, but the internal wiring differs: the 5SY7602-7 switches the neutral pole, whereas a 4P breaker switches all four poles identically. Verify the panel's neutral isolation scheme before substituting — if the original design relied on a solid neutral bar through the breaker, the 5SY7602-7's switched neutral may require re-termination.

MPN
5SY7602-7