Siemens 5SY7606-6 — 4-Pole MCB (DIN Rail)

Siemens SENTRON 5SY7606-6 MCB, 4P, B Curve, 6 A, 15/40 kA

MPN5SY7606-6
Active

Siemens SENTRON miniature circuit breaker, 5SY7606-6, 4-pole (3P+N), B tripping characteristic, 6 A rated, 15 kA (EN 60898) / 40 kA (IEC 60947-2), 4 MW, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7606-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY7606-6 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC6 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY7606-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 6089815 kA
Rated breaking capacity, per IEC 60947-240 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY7606-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY7606-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

The Siemens SENTRON 5SY7606-6 is a 4-pole miniature circuit breaker (3P+N) with a B tripping characteristic, rated 6 A at AC. It occupies 4 modular width units on a DIN rail and is designed for snap-on quick assembly in any mounting position. The B curve trips between 3 and 5 times rated current, making it the standard choice for resistive and general-purpose loads in commercial and industrial distribution boards — not for motor starting or high-inrush transformer circuits, where a C or D curve would be specified.

Breaking capacity and selectivity

Rated short-circuit breaking capacity is 15 kA per EN 60898 and 40 kA per IEC 60947-2. The 40 kA figure under 60947-2 is the industrial rating — it tells you this breaker can safely interrupt a fault up to that level without upstream devices needing to clear it. That matters for coordination studies: at 40 kA SCCR, this MCB can be the sole overcurrent device on a branch in a 400 V panel, provided the available fault current stays under that threshold. The energy limitation class 3 means it limits let-through energy during a short circuit, reducing stress on downstream wiring and connected equipment.

Thermal derating and ambient conditions

Rated 6 A at 35 °C ambient. Above that, derate linearly: 5.56 A at 45 °C, 5.41 A at 50 °C, 5.25 A at 55 °C, 5.09 A at 60 °C. If the panel runs hot — near a transformer or in a sealed enclosure — size the branch load against the derated figure, not the 6 A nameplate. Operating range spans -40 °C to 75 °C, with humidity limits of 95% up to 55 °C, 55% up to 70 °C, and 35% at 75 °C. Pollution degree 3 (conductive pollution or dry non-conductive that becomes conductive with condensation) is the rating for industrial control panels where the breaker sees the environment directly.

Physical fit and panel integration

Dimensions: 72 mm wide (4 MW), 90 mm high, 76 mm deep. Installation depth is 70 mm — the extra 6 mm is the front projection of the toggle and terminals. Combined terminals top and bottom accept busbar and conductor in the same clamp. IP20 with connected conductors, so it's protected against finger contact but not against water ingress — standard for enclosed distribution boards. Touch protection is integrated (fingertip-safe terminals). Halogen-free and silicon-free construction matters for environments where outgassing contaminates sensitive electronics or clean-room processes.

Frequently asked questions

How do I get current pricing and availability for 5SY7606-6?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through our independent sourcing channels.

What is the difference between 5SY7606-6 and 5SY4140-7?

The 5SY4140-7 is a 4-pole C-curve MCB rated 40 A — a different current rating and trip characteristic. The 5SY7606-6 is a 6 A B-curve. They share the same 4 MW DIN-rail footprint and SENTRON platform, so the 5SY7606-6 will physically fit a panel designed around the 5SY4140-7, but the branch load must be sized for 6 A, not 40 A.

What compliance documentation does Siemens provide for 5SY7606-6?

The 5SY7606-6 carries ratings per EN 60898 (15 kA) and IEC 60947-2 (40 kA). Standard Siemens documentation includes CE declaration of conformity and manufacturer's test certificates. RoHS and REACH compliance is standard for the SENTRON range.