Skip to main content
Siemens 5SY7606-8 — Miniature Circuit Breakers (MCB)

Siemens 5SY7606-8 SENTRON MCB, 6 A, D Curve, 4P, 15/40 kA

MPN5SY7606-8
Active

Siemens SENTRON 5SY7 series, 5SY7606-8 miniature circuit breaker, 4-pole (3P+N), rated current 6 A, tripping characteristic D, 400 V AC, breaking capacity 15 kA (EN 60898) / 40 kA (IEC 60947-2).

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY7606-8 — Ratings
ParameterValue
Overvoltage categoryIII
5SY7606-8 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

Siemens 5SY7606-8 — SENTRON MCB, 6 A, D Curve, 4P

The Siemens 5SY7606-8 is a 4-pole (3P+N) miniature circuit breaker from the SENTRON 5SY7 series, rated at 6 A with a D tripping characteristic at 400 V AC. Breaking capacity is 15 kA per EN 60898 and 40 kA per IEC 60947-2, with a 5 kA rating under UL 1077 / CSA C22.2 No. 235. That 40 kA IEC figure gives you headroom for high-fault installations; the 15 kA EN rating covers the standard domestic/commercial panel spec.

Mounting and wiring — panel fit

Touch protection is built in; the unit is sealable. Ambient range -40 to +75 °C operating, storage -40 to +70 °C. Halogen-free and silicon-free construction, so it won't outgas corrosive compounds in sensitive environments like data centers or medical equipment.

Suitable for mechanical engineering and industrial applications per the manufacturer. Overvoltage category III, pollution degree unspecified but typical for this class. Compliance with EN 60898 and IEC 60947-2 is listed; UL 1077 / CSA C22.2 No. 235 recognized for the 5 kA AC rating. The product is classified as F per DIN EN 61346-2 and DIN EN 81346-2.

Frequently asked questions

What is the breaking capacity of 5SY7606-8?

15 kA per EN 60898 and 40 kA per IEC 60947-2 at 400 V AC. For DC circuits, it's rated 15 kA at 72 V per IEC 60947-2. Under UL 1077 / CSA C22.2 No. 235, the AC breaking capacity is 5 kA.

Will 5SY7606-8 drop into a panel designed for 5SY6602-8?

Both are 4-pole SENTRON MCBs on the same DIN-rail footprint (72 mm wide, 4 width units), so the mechanical fit is identical. The difference is in ratings: 5SY7606-8 is 6 A D curve; 5SY6602-8 is a different current/curve variant. Check your branch circuit's required ampacity and coordination before swapping.

What compliance documentation is available for 5SY7606-8?

The MCB carries EN 60898 and IEC 60947-2 ratings, plus UL 1077 / CSA C22.2 No. 235 recognition for the 5 kA AC rating. It is halogen-free and silicon-free. Standard Siemens SENTRON documentation (declaration of conformity, CE marking) applies; specific certificates are available on request at quote time.

Where can I buy 5SY7606-8 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock count or lead-time number is published here. Submit an RFQ for a firm delivery commitment.

MPN
5SY7606-8