Skip to main content
Siemens 5SY7613-8 — 4-Pole MCB (DIN Rail)

Siemens 5SY7613-8 SENTRON MCB, 4P, D Curve, 13 A, 15/25 kA

MPN5SY7613-8
Active

Siemens SENTRON 5SY7 series miniature circuit breaker, 4-pole (3P+N), D tripping characteristic, 13 A rated, 50/60 Hz, 400 V AC, 15 kA (EN 60898) / 25 kA (IEC 60947-2) breaking capacity, IP20, quick-assembly mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY7613-8 — Identification
ParameterValue
Type / order code5SY7
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY7613-8 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated current (In), AC13 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY7613-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity (Icn), per EN 6089815 kA
Rated breaking capacity, per IEC 60947-225 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY7613-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY7613-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY7613-8 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

It's rated for 13 A at 400 V AC, 50/60 Hz, and carries a 15 kA breaking capacity per EN 60898 or 25 kA per IEC 60947-2. This is a quick-assembly mount part with a 72 mm width (4 width units) and 76 mm depth, fitting standard DIN-rail enclosures.

The IP20 rating (with conductors connected) is typical for inside a locked panel; not for wet or outdoor exposure without a secondary enclosure. That's a generous wire range for a 13 A breaker — useful when feeding a downstream subpanel or paralleling through a distribution block. The touch-protected design meets the usual safe-finger requirement for live panel work.

The 25 kA under IEC 60947-2 gives headroom for industrial panels with higher prospective fault current — useful when coordinating with an upstream molded-case breaker or fused disconnect. The D curve's magnetic trip threshold (10–20× In) means it won't trip on motor inrush, but it will clear a hard short fast enough to protect downstream wiring.

Frequently asked questions

How do I get current pricing and availability for 5SY7613-8?

Submit an RFQ through the site. The part is sourced to order via independent distribution; availability and current pricing are confirmed at quote time.

What is 5SY7613-8's listed depth?

76 mm, with an installation depth of 70 mm. Width is 72 mm (4 width units), height 90 mm.

What wire sizes does this breaker accept?

Solid or stranded conductors from 0.75 mm² up to 35 mm² on both top and bottom combined terminals.

Will 5SY7613-8 drop into a panel specified around 5SY7140-8CC without rewiring?

Not without checking the load. Both are 4-pole SENTRON breakers with the same footprint (72 mm wide, 76 mm deep) and terminal range, but the 5SY7140-8CC is a 40 A C-curve — the 13 A D-curve here is a different rating and characteristic. If the panel was wired for 40 A conductors, the 13 A breaker will physically fit, but the circuit protection will mismatch the load.

MPN
5SY7613-8