Skip to main content
Siemens 5SY7625-8 — Miniature Circuit Breakers (MCB)

Siemens 5SY7625-8 SENTRON MCB, 25A 4P D-Curve, 15/25kA

MPN5SY7625-8
Active

Siemens SENTRON 5SY7 series, miniature circuit breaker, 25 A, 4-pole (3P+N), D tripping characteristic, 15 kA (EN 60898) / 25 kA (IEC 60947-2), 400 V AC, 4 MW, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY7625-8 — Ratings
ParameterValue
Overvoltage categoryIII
5SY7625-8 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

The Siemens 5SY7625-8 is a SENTRON miniature circuit breaker rated 25 A at 400 V AC, 4-pole (3P+N), with a D tripping characteristic. Breaking capacity is 15 kA per EN 60898 and 25 kA per IEC 60947-2, with a DC rating of 15 kA per IEC 60947-2.

Breaking capacity and standard compliance

The 15 kA rating under EN 60898 covers the standard household/commercial installation curve; the 25 kA under IEC 60947-2 is the industrial rating, meaning this breaker can interrupt fault currents up to 25 kA at 400 V AC without welding its contacts or cascading failure upstream. The DC rating of 15 kA per IEC 60947-2 covers DC-side faults in rectified supplies or battery banks. UL 1077 and CSA C22.2 No. 235 recognition at 5 kA confirms suitability for North American supplementary protection applications.

Snap-on mounting to DIN rail, any orientation. The 4 MW width (72 mm) means it occupies four 18 mm slots — plan your rail fill accordingly. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz — suitable for machine-mounted panels.

Environmental and compliance documentation

Halogen-free and silicon-free construction, sealable for tamper-proofing. Ambient temperature range -40 °C to 75 °C, with humidity derating: max 95% RH at 55 °C, tapering to 35% RH at 75 °C.

Frequently asked questions

What is the breaking capacity of 5SY7625-8?

15 kA per EN 60898, 25 kA per IEC 60947-2 at 400 V AC, and 15 kA DC per IEC 60947-2. UL 1077/CSA C22.2 No. 235 rating is 5 kA.

What is the difference between 5SY7625-8 and 5SY7140-8CC?

The 5SY7140-8CC is a 40 A, 4-pole, C-curve variant. The 5SY7625-8 is 25 A with a D-curve. Both share the same 4 MW footprint and SENTRON platform, but the D-curve on the 25 A unit handles higher inrush — swap only if the load's starting current is within the C-curve magnetic trip threshold (5–10× In vs 10–20× In).

Where can I buy 5SY7625-8?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SY7625-8