Skip to main content
Siemens 5SY8104-7 — 1-Pole MCB (DIN Rail)

Siemens 5SY8104-7 SENTRON MCB, C-Curve, 1P, 50 kA IEC

MPN5SY8104-7
Active

Siemens SENTRON, miniature circuit breaker, 5SY8104-7, 1-pole, C characteristic, 50 kA at 400 V AC (IEC 60947-2), 15 kA at 60 V DC, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY8104-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY8104-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY8104-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY8104-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The 5SY8104-7 is a 1-pole SENTRON miniature circuit breaker with a C tripping characteristic, rated for 400 V AC (50/60 Hz) and 60 V DC. On the DC side, it's rated 15 kA at 60 V DC, which covers most control-circuit and battery-bank applications. The UL 1077 listing at 5 kA confirms it's recognized as a supplementary protector in North American panels, not a branch-circuit rated breaker.

The operating temperature range is -40 °C to 75 °C, with humidity derating above 55 °C (95% RH up to 55 °C, 55% RH up to 70 °C, 35% RH up to 75 °C). That's wide enough for unheated outdoor cabinets in cold climates, but watch the humidity curve if the panel sees condensation.

Mechanical endurance and compliance

Vibration resistance per IEC 60068-2-6: ±1 mm at 5 to 25 Hz, 50 m/s² at 25 to 150 Hz. Halogen-free and silicon-free construction, which matters for clean-room or semiconductor-adjacent installations where outgassing contaminates optics or wafers. Sealable terminals are standard, allowing lockout/tagout compliance without add-on accessories.

Frequently asked questions

What is the breaking capacity of 5SY8104-7 at 400 V AC?

50 kA per IEC 60947-2 at 400 V AC. Under UL 1077 it's rated 5 kA as a supplementary protector.

Will 5SY8104-7 drop into a panel specified for 5SY4101-7CV without rewiring?

Both are 1-pole, 1-module-width SENTRON MCBs with the same DIN-rail footprint and terminal layout. The 5SY8104-7 carries a higher breaking capacity (50 kA vs the 5SY4101-7CV's lower rating), so it's a functional upgrade in the same physical envelope — no rewiring needed, but verify the trip characteristic matches your coordination study.

Where can I buy 5SY8104-7 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What compliance documentation does Siemens provide for 5SY8104-7?

The part is certified under IEC/EN 60947-2 and UL 1077. It's halogen-free and silicon-free. Standard compliance documentation (CE, UKCA, EAC) is available from Siemens; RoHS and REACH declarations are typically included with the shipment or downloadable from the Siemens support portal.