Siemens 5SY8106-7 — 1-Pole MCB (DIN Rail)

Siemens 5SY8106-7 SENTRON MCB, C-Curve 1P, 50 kA IEC

MPN5SY8106-7
Active

Siemens SENTRON 5SY8106-7, 1-pole miniature circuit breaker, C-curve, 50 kA at 400 V AC per IEC 60947-2, 5 kA per UL1077, 18 mm width, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY8106-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY8106-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY8106-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY8106-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY8106-7 is a 1-pole miniature circuit breaker from the SENTRON family, rated to interrupt 50 kA at 400 V AC per IEC 60947-2 — that is the headline number that governs fault clearance in an industrial panel. On the DC side it handles 15 kA at 60 V (72 V max), and for North American installs it carries a 5 kA SCCR under UL1077. Mounting position is unrestricted, and the sealable toggle accepts a padlock for lockout/tagout — handy when an MRO planner needs to isolate a circuit for line-down work. Rated IP20 with conductors connected, so it lives inside a closed enclosure, not in a washdown zone.

Standards, approvals, and environmental limits

This breaker carries triple-standard certification: IEC 60947-2 (the industrial standard for low-voltage switchgear), EN 60947-2 (European harmonized), and UL1077 (North American supplementary protector). That means it is accepted in panels destined for Europe, the UK, and North America without a separate component-level approval chase. Operating temperature spans -40 °C to 75 °C, with humidity derating: up to 95% RH at 55 °C, dropping to 35% RH at 75 °C. Vibration resistance per IEC 60068-2-6 (±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz) means it holds up on a machine skid or near a conveyor drive without false trips. Halogen-free and silicon-free construction is a plus for clean rooms or coating lines where outgassing contaminants are a concern.

Neutral conductor switching is not integrated (single-pole only), so the neutral bar stays separate. Rated for 50/60 Hz AC supply. Single-phase operation at 440 V AC, multi-phase at 440 V AC — so it handles 400 V line-to-line or 230/277 V line-to-neutral circuits common in industrial distribution. The 10 000 mechanical operating cycles typical service life means it will outlast most machine refreshes under normal switching duty.

Frequently asked questions

What are the key breaking capacity ratings for the 5SY8106-7?

50 kA at 400 V AC per IEC 60947-2, 15 kA at 60 V DC per IEC 60947-2, and 5 kA per UL1077 for North American acceptance. The C-curve trips at 5–10× rated current.

Where can I buy the 5SY8106-7 and get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial response.

Does the 5SY8106-7 comply with North American standards?

Yes, it carries a UL1077 and CSA C22.2 No. 235 listing with a 5 kA SCCR, alongside the primary IEC 60947-2 certification. Suitable for panels destined for US or Canadian installations as a supplementary protector.

What compliance documentation is available for the 5SY8106-7?

The breaker is halogen-free and silicon-free, which supports RoHS and REACH compliance. The IEC/EN 60947-2 and UL1077 certifications cover the safety and performance documentation typically required for an MRO or OEM BOM package.

MPN
5SY8106-7