Siemens 5SY8106-8 — 1-Pole MCB (DIN Rail)

Siemens 5SY8106-8 SENTRON MCB, 6 A, D Curve, 50 kA, 1-Pole

MPN5SY8106-8
Active

Siemens SENTRON 5SY8106-8 miniature circuit breaker, 1-pole, 6 A rated, D tripping characteristic, 50 kA breaking capacity per IEC 60947-2, 18 mm width, 76 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY8106-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY8106-8 — Electrical & Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY8106-8 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY8106-8 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens 5SY8106-8 is a SENTRON miniature circuit breaker, single-pole, rated 6 A with a D tripping characteristic. The D curve means it tolerates inrush currents up to 10–20× the rated current — sized for motor and transformer branch circuits where the start-up surge would nuisance-trip a B or C curve. Breaking capacity is 50 kA at 400 V AC per IEC 60947-2, so it safely interrupts high fault currents without cascading upstream. That rating puts it in the high-interrupting category for industrial panels, not residential load centers. Mounting is snap-on DIN rail, 18 mm wide (1 MW unit). The 76 mm depth fits standard distribution boards; the 70 mm installation depth means it sits flush with the rail. IP20 with connected conductors — panel internal only, not for wet or washdown areas. Temperature range -40 to 75 °C, so it handles unheated enclosures and hot cabinet interiors.

Integration Notes

Combined terminal top and bottom — line and load can land on either side, simplifying busbar routing. Touch protection integrated. Sealable for panel lockout/tagout. Halogen-free and silicon-free construction, relevant for clean-room or semiconductor-adjacent installations where outgassing is a concern. Degree of pollution 3 rating means it's suitable for conductive environments (condensation, occasional dust). Overvoltage category III — designed for fixed installation downstream of the main distribution board, not for equipment-level (Cat II) or utility-meter (Cat IV) positions.

Frequently asked questions

What is the breaking capacity of 5SY8106-8?

50 kA at 400 V AC per IEC 60947-2. At DC (72 V max) it's rated 15 kA per the same standard.

Will 5SY8106-8 drop into a panel specified around 5SY4140-7?

Both are 1-pole MCBs on 18 mm DIN-rail footprint, so the mechanical fit is the same. The 5SY8106-8 is a D-curve 6 A unit; the 5SY4140-7 is a different rating and characteristic — verify the branch circuit's required current and trip curve before substituting.

Where can I buy the 5SY8106-8?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

What compliance documentation is available for 5SY8106-8?

The part carries IEC 60947-2 ratings. The SENTRON series is generally RoHS and REACH compliant per Siemens standard declarations; request the specific declaration of conformity with your RFQ.