Siemens 5SY8110-7 SENTRON MCB, 1P C-Curve, 40 kA IEC, 76 mm

MPN5SY8110-7
Active

Siemens SENTRON 5SY8110-7, 1-pole C-curve miniature circuit breaker, 40 kA at 400 V AC (IEC 60947-2), 15 kA DC, 18 mm width, 76 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY8110-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Pole design1P
Application suitabilityMechanical engineering / industry
5SY8110-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY8110-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY8110-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

The Siemens SENTRON 5SY8110-7 is a 1-pole miniature circuit breaker with C-curve trip characteristic, rated to interrupt 40 kA at 400 V AC per IEC 60947-2 and 15 kA at 60 V DC per the same standard. That 40 kA figure is the high-fault rating that matters for industrial panel feed circuits where upstream transformers or large motor drives can deliver substantial short-circuit current — this breaker clears it without cascading to the main. For DC circuits, the 15 kA rating at 60 V covers most 24 V and 48 V control bus applications, though the maximum DC operating voltage is 72 V.

Fit and footprint

At 18 mm wide (1 modular unit) and 76 mm deep, this breaker slots into any standard DIN-rail enclosure without protruding past the gland plate on most 80 mm deep panels.

Vibration resistance per IEC 60068-2-6 covers ±1 mm at 5–25 Hz and 50 m/s² at 25–150 Hz, so it holds up on machine-mounted sub-panels near presses or conveyors. The 10 000 mechanical operating cycles typical service life covers routine switching for a decade or more in most industrial control panels.

Frequently asked questions

What is the breaking capacity of 5SY8110-7 at 400 V AC?

40 kA per IEC 60947-2 at 400 V AC. For DC circuits, it is rated 15 kA at 60 V DC (max 72 V operating voltage). Under UL 1077, the rating is 5 kA.

What compliance standards does 5SY8110-7 meet?

It is certified to IEC/EN 60947-2 and UL 1077. The housing is halogen-free and silicon-free. The IP20 rating applies with connected conductors, suitable for enclosed panel installation.

Where can I buy 5SY8110-7 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will 5SY8110-7 replace 5SY4140-7 in an existing panel?

Both are 1-pole SENTRON MCBs with the same 18 mm width and DIN-rail mount. The 5SY8110-7 carries a C-curve and 40 kA IEC breaking capacity, while the 5SY4140-7 is a different variant — verify the trip characteristic and interrupting rating match your panel's fault study before swapping. The mechanical footprint is identical.