Siemens 5SY8140-7 SENTRON MCB, 1P C 40 A, 25 kA

MPN5SY8140-7
Active

Siemens SENTRON, miniature circuit breaker, 5SY8140-7, 1-pole, C characteristic, 40 A (45 °C), 25 kA IEC 60947-2, 15 kA DC, 5 kA UL 1077, 1 MWU, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY8140-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles1
Application suitabilityMechanical engineering / industry
5SY8140-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Overvoltage categoryIII
5SY8140-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units1
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY8140-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

Ambient temperature derating is built in: at 50 °C the continuous rating drops to 39 A, at 55 °C to 37.96 A. That matters if the breaker sits inside a hot, poorly ventilated enclosure near the mill.

The quick-assembly system and combined terminals top and bottom let a wireman land incoming and outgoing conductors without re-terminating the busbar. Sealable and touch-protected, with IP20 rating once conductors are connected. Halogen-free and silicon-free construction matters when the breaker lives near sensitive electronics or in areas with strict smoke-toxicity specs.

Listed under UL 1077 and CSA C22.2 No. 235 with a 5 kA interrupting rating — enough for North American panelboard branch circuits. The IEC 60947-2 rating of 25 kA covers most European and global industrial installations. Vibration resistance per IEC 60068-2-6 (±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz) means it shrugs off the vibration on a crusher floor. Production status is current; the part is in active manufacture.

Frequently asked questions

What is the breaking capacity of the 5SY8140-7?

25 kA per IEC 60947-2 at 400 V AC, 15 kA at DC per the same standard, and 5 kA per UL 1077 / CSA C22.2 No. 235.

Will the 5SY8140-7 drop into a panel specified for 5SY4116-7CV?

Both are 1-pole SENTRON MCBs with the same 18 mm width and DIN-rail mounting, so mechanical fit is identical. The 5SY8140-7 carries a 40 A C-curve versus the lower-rated 5SY4116-7CV; verify the branch circuit ampacity and coordination before swapping.

Where can I buy the 5SY8140-7 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.