Siemens SENTRON 5SY8216-8, 2-pole miniature circuit breaker, D tripping characteristic, 30 kA at 400 V AC per IEC 60947-2, 36 mm wide, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY8216-8 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY8216-8 — Electrical
ParameterValue
Number of poles2
5SY8216-8 — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY8216-8 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY8216-8 — Environmental
ParameterValue
Pollution degree3
5SY8216-8 — Specifications
ParameterValue
At AC rated value400 V
With single-phase operation at AC rated value440 V

Product details

The Siemens SENTRON 5SY8216-8 is a 2-pole miniature circuit breaker with a D tripping characteristic, rated 30 kA breaking capacity at 400 V AC per IEC 60947-2. For DC circuits, it's rated 15 kA at 60 V (max 72 V), so it also handles battery-backed or rectified supplies in the same panel. Mounting is standard DIN rail — snaps onto a 35 mm rail, any position, with the quick-assembly system.

Compliance documentation is straightforward: it carries IEC / EN 60947-2 and UL 1077 approvals, which covers most industrial and commercial panels globally.

Deployment context

The 10 000 mechanical operating cycles mean it's built for occasional switching, not daily load-break duty — that's what a contactor is for. Ambient temperature range is -40 °C to 75 °C, with derating above 55 °C per the humidity table (max 95% RH at 55 °C, dropping to 35% at 75 °C). That covers outdoor enclosures in cold climates and hot machinery cabinets alike. Vibration resistance per IEC 60068-2-6 (±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz) means it holds up on a conveyor drive panel or a compressor skid.

Frequently asked questions

How do I get current pricing and availability for 5SY8216-8?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

Will 5SY8216-8 drop into a panel that was specified around 5SY4140-7 without rewiring?

Both are 2-pole SENTRON MCBs on the same DIN-rail footprint, but the 5SY8216-8 has a D-curve (high-inrush loads) while the 5SY4140-7 is a different characteristic. The physical fit is the same — 36 mm wide, 76 mm deep, 90 mm tall — but verify the tripping curve matches your load before swapping.

What compliance documentation does this brand provide for 5SY8216-8?

The breaker carries IEC / EN 60947-2 and UL 1077 approvals. It is halogen-free and silicon-free, which satisfies clean-room material restrictions. Pollution degree 3 and overvoltage category III are declared for industrial fixed installations.