Siemens 5SY8216-8BB08 — 2-Pole MCB (DIN Rail)

Siemens 5SY8216-8BB08 SENTRON MCB, 2-pole 16A D-curve, 30kA

MPN5SY8216-8BB08
Active

Siemens SENTRON 5SY8216-8BB08, 2-pole miniature circuit breaker, 16 A rated current, D tripping characteristic, 30 kA breaking capacity per IEC 60947-2, 2 MW width, magnetic-only trip.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY8216-8BB08 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Application environmentMechanical engineering / industry
5SY8216-8BB08 — Electrical
ParameterValue
Number of poles2
5SY8216-8BB08 — Protection
ParameterValue
Tripping characteristic classD
Overvoltage categoryIII
5SY8216-8BB08 — Mechanical
ParameterValue
Modular width units2
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Min.-40 °C
Max.75 °C
Protection degree (IP)IP20, with connected conductors
5SY8216-8BB08 — Environmental
ParameterValue
Pollution degree3

Product details

The Siemens SENTRON 5SY8216-8BB08 is a 2-pole miniature circuit breaker (MCB) with a D tripping characteristic, rated 16 A at AC and a breaking capacity of 30 kA per IEC 60947-2. It's a magnetic-only trip design — no thermal element — so it responds purely to overcurrent, not to sustained low-level overloads. That makes it a fit for applications where you want short-circuit protection but handle overloads separately (e.g., via a motor-protective relay).

Compliance and approvals

Rated per IEC 60947-2 (30 kA) and also carries a UL 1077 / CSA C22.2 No. 235 rating of 5 kA — that's the supplementary-protector rating for North American panels where the MCB is used as a branch-circuit component, not a main. Halogen-free and silicon-free construction, sealable, with touch protection on the terminals. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz.

Frequently asked questions

What is the breaking capacity of 5SY8216-8BB08?

30 kA per IEC 60947-2 at 400 V AC; also rated 5 kA per UL 1077 and CSA C22.2 No. 235.

What does the D tripping characteristic mean for this breaker?

The D curve allows higher inrush currents without tripping — typically used for motor, transformer, or welding loads where the start-up surge is several times the rated current.

Where can I buy 5SY8216-8BB08 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

Will 5SY8216-8BB08 drop into a panel specified for 5SY7210-7CC?

Both are 2-pole SENTRON MCBs on the same DIN-rail footprint, but the 5SY8216-8BB08 is a 16 A D-curve with 30 kA IEC breaking capacity, while the 5SY7210-7CC is a different rating and characteristic — verify the specific load and coordination requirements before swapping.

MPN
5SY8216-8BB08