Skip to main content
Siemens 5SY8314-7 — 3-Pole MCB (DIN Rail)

Siemens 5SY8314-7 SENTRON MCB, 3P C-Char, 70 kA IEC, 400 VAC

MPN5SY8314-7
Active

Siemens SENTRON 5SY8314-7, miniature circuit breaker, 3-pole, C tripping characteristic, 70 kA at 400 VAC per IEC 60947-2, 15 kA DC, 5 kA per UL 1077, 50/60 Hz, IP20, current production.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY8314-7 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY8314-7 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per IEC 60947-270 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Pollution degree3
5SY8314-7 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)0.9 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY8314-7 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY8314-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

The 5SY8314-7 is a SENTRON 3-pole miniature circuit breaker with a C tripping characteristic, rated at 400 VAC and delivering 70 kA interrupting capacity per IEC 60947-2 — that's the fault-clearing figure that governs the arc-flash rating downstream. At DC it holds 15 kA per the same standard; under UL 1077 it's listed at 5 kA, so for a UL 508A panel the branch-circuit SCCR must stay at or below that limit. Mounting position is any. Depth is 76 mm (70 mm behind the panel surface). Vibration resistance per IEC 60068-2-6 is ±1 mm at 5 to 25 Hz and 50 m/s² at 25 to 150 Hz — it holds up on a mill table or conveyor drive panel without nuisance trips from mechanical shock.

Sourcing reality

Frequently asked questions

What compliance documentation does this brand provide for 5SY8314-7?

The manufacturer provides RoHS and REACH declarations on request. The part is certified to IEC / EN 60947-2 and UL 1077, and the housing is halogen-free and silicon-free.

Can I buy 5SY8314-7 here and how do I get a price?

Sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ with your target quantity and delivery window; availability and current pricing are confirmed at quote time.

MPN
5SY8314-7