Skip to main content
Siemens 5SY8401-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY8401-7 SENTRON MCB, 4P C-curve 1A, 70kA IEC

MPN5SY8401-7
Active

Siemens SENTRON 5SY8401-7, 4-pole miniature circuit breaker, C-curve, 1 A rated current, 70 kA breaking capacity per IEC 60947-2, 440 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY8401-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY8401-7 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC1 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
5SY8401-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity, per IEC 60947-270 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SY8401-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY8401-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY8401-7 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

Siemens SENTRON 5SY8401-7 — 4-pole C-curve MCB, 1 A, 70 kA

It belongs to the SENTRON series, designed for mechanical engineering and industrial panel applications where branch-circuit protection and selectivity matter.

Thermal derating and environmental limits

At 45 °C ambient the 1 A rating holds; at 50 °C it derates to 0.98 A, at 55 °C to 0.95 A. The surrounding temperature influence spec caps humidity at 95% up to 55 °C, 55% up to 70 °C, and 35% up to 75 °C — so in a sealed, non-ventilated enclosure near heat sources, check the actual ambient against the derating curve.

Frequently asked questions

What is the breaking capacity of 5SY8401-7 under different standards?

Per IEC 60947-2 it is rated 70 kA at 400 V AC and 15 kA DC; per UL 1077 and CSA C22.2 No. 235 it is rated 5 kA.

Where can I buy 5SY8401-7 and how is it quoted?

The 5SY8401-7 is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — no stock or price figures are published here.

What compliance documentation does Siemens provide for 5SY8401-7?

The breaker is certified to IEC 60947-2, UL 1077, and CSA C22.2 No. 235. It is halogen-free and silicon-free per the manufacturer's declaration.

MPN