Skip to main content
Siemens 5SY8408-8 — 4-Pole MCB (DIN Rail)

Siemens 5SY8408-8 SENTRON MCB, 4P, D-curve, 8 A, 40 kA

MPN5SY8408-8
Active

Siemens SENTRON 5SY8 series, miniature circuit breaker, 4-pole, D characteristic, 8 A rated current, 400 V AC, 40 kA IEC 60947-2, 72 mm wide, 76 mm deep.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY8408-8 — Identification
ParameterValue
Type / order code5SY8
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY8408-8 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated current (In), AC8 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY8408-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity, per IEC 60947-240 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY8408-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY8408-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY8408-8 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SY8408-8 is a SENTRON 5SY8 miniature circuit breaker, 4-pole with D tripping characteristic, rated 8 A at 400 V AC. This is the current-production variant — lifecycle status is active, so it's the part you spec into a new BOM or order as a direct replacement for an existing 5SY8 install.

At 8 A rated current, it's a common feeder for a small motor group or a control transformer. If you're specifying for a UL 508A panel, the UL 1077/CSA C22.2 No. 235 rating is 5 kA — a different standard, so verify the SCCR requirement against your assembly rating. Overvoltage category III means it's rated for fixed-installation distribution boards, not just downstream equipment. The 72 mm width (4 width units at 18 mm each) is the standard DIN-rail footprint for a 4-pole MCB — it occupies four adjacent positions on the rail.

Any mounting position is acceptable. Humidity derating applies: max 95% RH at 55 °C, 55% at 70 °C, 35% at 75 °C. The terminals accept solid or stranded copper from 0.75 mm² up to 35 mm², with a tightening torque of 2.5 to 3.5 N·m. Sealable (padlockable) per the spec, which matters for lockout/tagout compliance.

Rated per IEC 60947-2 (40 kA at 400 V AC, 15 kA at 72 V DC) and UL 1077 / CSA C22.2 No. 235 (5 kA). Halogen-free and silicon-free construction. The product designation per DIN EN 61346-2 and DIN EN 81346-2 is function code F (protective device). Touch protection is provided on the terminals.

Frequently asked questions

Who supplies 5SY8408-8 and how is it quoted for volume purchases?

Sourced and quoted to order against an RFQ through independent industrial-automation distribution. Availability and current pricing are confirmed at quote time — no stock or price figures are published here.

What compliance documentation does Siemens provide for 5SY8408-8?

The part carries IEC 60947-2 and UL 1077/CSA C22.2 No. 235 ratings. It is halogen-free and silicon-free. Standard Siemens documentation includes a CE declaration of conformity and the datasheet; RoHS and REACH compliance statements are available from the manufacturer on request.

MPN
5SY8408-8