Skip to main content
Siemens 5SY8416-8 — Miniature Circuit Breakers (MCB)

Siemens 5SY8416-8 SENTRON MCB, 4P, D-curve, 30 kA

MPN5SY8416-8
Active

Siemens SENTRON 5SY8416-8 miniature circuit breaker, 4-pole, D tripping characteristic, 30 kA at 400 V AC per IEC 60947-2, 72 mm wide.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY8416-8 — Ratings
ParameterValue
Overvoltage categoryIII
5SY8416-8 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

This Siemens SENTRON 5SY8416-8 is a 4-pole miniature circuit breaker with a D tripping characteristic, rated 30 kA at 400 V AC per IEC 60947-2 and 15 kA at 60 V DC. The D-curve means it handles high inrush currents from motor or transformer loads without nuisance tripping — the magnetic trip kicks in at 10 to 20 times rated current, so it's the go-to for drives and welding gear, not lighting or general distribution.

The 15 kA at 60 V DC covers DC bus or battery-backed loads. The D-curve (tripping characteristic class D) is the key selection parameter here. Magnetic trip between 10× and 20× In means it ignores the startup surge of a motor or a power supply — you won't get a false trip on a cold start.

The 72 mm width (4 modular units) is standard for a 4-pole MCB; it occupies the same slot as any other 4-module wide device. Sealable with a lead seal or sticker for tamper-evident panels.

Frequently asked questions

Where can I buy the 5SY8416-8 and what is the lead time?

The 5SY8416-8 is sourced and quoted to order through our independent distribution network. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time and price.

What is the breaking capacity of the 5SY8416-8?

30 kA at 400 V AC per IEC 60947-2, and 15 kA at 60 V DC per IEC 60947-2. Under UL 1077 it's rated 5 kA.

Will the 5SY8416-8 drop into a panel specified around the 5SY4140-7?

Both are 4-pole SENTRON MCBs with the same 72 mm width and DIN-rail mount, so the form factor and footprint are identical. The difference is the tripping curve — the 5SY8416-8 is a D-curve (for motor/transformer loads), while the 5SY4140-7 uses a different characteristic. No rewiring needed if the curve matches your load; if the panel was coordinated for a B or C curve, swapping to a D-curve changes the selectivity and nuisance-trip behavior.

What compliance documentation does Siemens provide for the 5SY8416-8?

The breaker is certified to IEC/EN 60947-2 and UL 1077. It is halogen-free and silicon-free. For specific declarations (RoHS, REACH, CE, UKCA), the manufacturer's documentation is available on request with the order.