Skip to main content
Siemens 5SY8416-8BB08 — 4-Pole MCB (DIN Rail)

Siemens 5SY8416-8BB08 SENTRON MCB, 4P D-16 A, 30 kA IEC

MPN5SY8416-8BB08
Active

Siemens SENTRON 5SY8416-8BB08, 4-pole miniature circuit breaker, D tripping characteristic, 16 A rated current, 400 V AC, 30 kA breaking capacity per IEC 60947-2, magnetic-only trip mechanism.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY8416-8BB08 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY8416-8BB08 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated current (In), AC16 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY8416-8BB08 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity, per IEC 60947-230 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY8416-8BB08 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY8416-8BB08 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY8416-8BB08 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

Deployment context

The 90 mm height fits standard 100 mm deep enclosures. IP20 with connected conductors means the busbar and wiring provide the touch protection; the breaker body alone is finger-safe only when wired. Rated for mechanical engineering and industrial environments per the suitability listing.

Frequently asked questions

Where can I buy 5SY8416-8BB08 and what is the lead time?

This part is sourced to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead-time commitment.

Will 5SY8416-8BB08 drop into a panel specified around 5SY3132-6 without rewiring?

No — the 5SY8416-8BB08 is a 4-pole D-curve 16 A breaker with magnetic-only trip, while the 5SY3132-6 is a different pole count and characteristic. The DIN-rail footprint (4 width units) may match, but the terminal arrangement and trip curve differ; verify the existing panel's wiring diagram before substituting.

What compliance documentation does this brand provide for 5SY8416-8BB08?

The breaker carries IEC 60947-2 (30 kA) and UL 1077 / CSA C22.2 No.235 (5 kA) ratings, with overvoltage category III. The SENTRON series typically provides CE, UKCA, and EAC declarations; specific RoHS/REACH statements are available from Siemens documentation for this order code.

MPN
5SY8416-8BB08