Siemens 5SY8425-8BB08 — 4-Pole MCB (DIN Rail)

Siemens 5SY8425-8BB08 SENTRON MCB, 4P, 25 A, D Curve, 30 kA

MPN5SY8425-8BB08
Active

Siemens SENTRON 5SY8425-8BB08, miniature circuit breaker, 4-pole, 25 A, D tripping characteristic, 30 kA (IEC 60947-2), 400 V AC, only magnetic tripping, 4 width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY8425-8BB08 — Identification
ParameterValue
Type / order code5SY8BB08
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY8425-8BB08 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY8425-8BB08 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity, per IEC 60947-230 kA
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY8425-8BB08 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY8425-8BB08 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY8425-8BB08 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens SENTRON 5SY8425-8BB08 is a 4-pole miniature circuit breaker rated 25 A at 400 V AC, with a D tripping characteristic and a breaking capacity of 30 kA per IEC 60947-2. It uses only magnetic tripping — no thermal bimetal — so it's built for short-circuit protection of circuits with high inrush loads like motor starters or transformers, where a standard thermal-magnetic breaker might nuisance-trip on startup.

The 30 kA breaking capacity at 400 V AC (IEC 60947-2) tells you this breaker can safely interrupt a fault current up to 30 kA without welding or exploding — that's the SCCR the panel needs to coordinate with upstream gear. The D curve means the magnetic trip threshold is 10 to 20 times rated current (250 to 500 A), which avoids nuisance trips on motor inrush or transformer magnetizing current.

Frequently asked questions

What is the breaking capacity of 5SY8425-8BB08?

30 kA at 400 V AC per IEC 60947-2.

Where can I buy 5SY8425-8BB08?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Does 5SY8425-8BB08 switch the neutral?

No, the neutral conductor is not switched — only the three phases are protected.