Siemens 5SY8601-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY8601-7 SENTRON MCB, C-curve 1A 4P 70kA

MPN5SY8601-7
Active

Siemens SENTRON 5SY8601-7 miniature circuit breaker, C-curve 1 A, 4-pole (3P+N), 70 kA breaking capacity per IEC 60947-2, 440 V AC, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY8601-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY8601-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SY8601-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY8601-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY8601-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY8601-7 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.2 W

Product details

SENTRON 5SY8601-7 — 1 A C-curve MCB, 4-pole, 70 kA

It is a 4-pole unit (3P+N) with neutral conductor switching, designed for AC circuits up to 440 V single- or multi-phase. The breaking capacity is 70 kA per IEC 60947-2, with a DC rating of 15 kA at up to 72 V.

The 15 kA DC rating at 72 V extends its use to DC control circuits, though the primary application is AC. Temperature derating is specified: 1 A at 45 °C, 0.98 A at 50 °C, 0.95 A at 55 °C. In a warm panel (e.g., near 50 °C), the effective continuous current drops to 0.98 A — factor this into load planning. The 4-pole design with neutral switching (3P+N) means the neutral is switched and protected, not just a solid link — required in some IEC installations for single-phase loads on a three-phase system.

Sealable, halogen-free, silicon-free — relevant for clean-room or food-bev environments where outgassing must be controlled.

The product designation follows EN 61346-2 and IEC 81346-2 (function code F). Suitability for mechanical engineering and industry is stated.

Frequently asked questions

Where can I buy 5SY8601-7 and how do I get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is 5SY8601-7's listed depth (76 mm) on this component line?

The depth is 76 mm, with an installation depth of 70 mm. Width is 72 mm (4 modular units), height 90 mm.

Will 5SY8601-7 drop into a panel that was specified around 5SY6332-7CC without rewiring?

Both are 4-pole SENTRON MCBs with the same modular width (4 MW = 72 mm) and DIN-rail mounting, so the physical footprint is identical. However, 5SY6332-7CC is a 32 A C-curve unit; the 5SY8601-7 is 1 A. The wiring and busbar arrangement are the same, but the load current rating is completely different — verify the branch circuit's ampacity before substitution.

What compliance documentation does this brand provide for 5SY8601-7 (RoHS, REACH, UL, IEC)?

Siemens provides RoHS, REACH, and IEC 60947-2 compliance documentation for the SENTRON 5SY series. The part is rated per IEC 60947-2 (70 kA breaking capacity) and carries overvoltage category III, pollution degree 3. Request the specific declaration with your RFQ.

MPN