Siemens 5SY8601-8 — 4-Pole MCB (DIN Rail)

Siemens 5SY8601-8 SENTRON MCB, 4P, D-curve, 1 A, 70 kA

MPN5SY8601-8
Active

Siemens SENTRON 5SY8601-8 miniature circuit breaker, 4-pole (3P+N), D tripping characteristic, 1 A rated current, 70 kA breaking capacity at AC per IEC 60947-2, IP20 with connected conductors.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY8601-8 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY8601-8 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC1 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY8601-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity, per IEC 60947-270 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY8601-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY8601-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

It breaks up to 70 kA at AC per IEC 60947-2 and 15 kA at DC per the same standard, with a UL 1077 / CSA C22.2 No. 235 interrupting rating of 5 kA.

D-curve and selectivity

The D tripping characteristic means this breaker holds through inrush up to 10–20× rated current before tripping magnetically. That suits loads with high starting surges — small transformers, solenoid banks, motor starters with contactor coils. For a 1 A rated device, expect the magnetic trip to pick up around 10–20 A instantaneous. Neutral conductor switching is built in (3P+N), so the neutral pole opens and closes with the phases. That matters for TN-S or TN-C-S systems where you want the neutral isolated during maintenance. The breaker is sealable, which lets a panel builder or inspector lock the toggle position after commissioning.

The 72 mm width corresponds to 4 modular units (18 mm per pole). Mounting position any, so you can orient it vertically or horizontally in a shallow enclosure. Rated for ambient temperatures from -40 °C to 75 °C, with derating above 45 °C: at 50 °C it carries 0.98 A, at 55 °C it carries 0.95 A.

Frequently asked questions

What is the breaking capacity of 5SY8601-8?

70 kA at AC per IEC 60947-2, 15 kA at DC per IEC 60947-2, and 5 kA per UL 1077 and CSA C22.2 No. 235. The 70 kA AC rating is the headline figure for industrial high-fault applications.

What is the tripping characteristic of 5SY8601-8?

D-curve — magnetic trip typically between 10× and 20× rated current (10–20 A for this 1 A breaker). Designed for loads with high inrush, such as small transformers and solenoid banks.

Where can I buy 5SY8601-8?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — no stock count or lead-time number published here.

What compliance documentation does Siemens provide for 5SY8601-8?

The breaker carries IEC 60947-2 and UL 1077 / CSA C22.2 No. 235 approvals. The housing is halogen-free and silicon-free. Standard Siemens declarations (CE, UKCA, RoHS, REACH) are available per the SENTRON series documentation.