Siemens 5SY8605-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY8605-7 SENTRON MCB, 4P C 0.5A, 70kA

MPN5SY8605-7
Active

Siemens SENTRON 5SY8605-7 miniature circuit breaker, 4-pole (3P+N), C-curve, 0.5 A rated current, 70 kA breaking capacity at 400 V AC per IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY8605-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY8605-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY8605-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity, per IEC 60947-270 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY8605-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY8605-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

The Siemens 5SY8605-7 is a SENTRON miniature circuit breaker (MCB) — a 4-pole unit (3P+N) with a C tripping characteristic, rated 0.5 A at 400 V AC, 50/60 Hz. It carries a 70 kA breaking capacity per IEC 60947-2 at 400 V AC, with 15 kA at DC under the same standard, and 5 kA per UL 1077 / CSA C22.2 No. 235.

Rated current is temperature-sensitive. At 45 °C ambient the 0.5 A rating holds; at 50 °C it derates to 0.49 A, at 55 °C to 0.47 A. The operating range spans -40 °C to 75 °C, with humidity limits stepping down as temperature rises — 95% RH up to 55 °C, 55% RH to 70 °C, 35% RH to 75 °C. If the panel runs hot, factor the derating into your load calculation.

Mounts in any position, uses the quick-assembly system for ganging multiple breakers. Touch protection is built in.

Construction and compliance

Halogen-free and silicon-free construction. Sealable for tamper-proofing in metering or critical circuits. The neutral conductor is switched (3P+N configuration). Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz.

This is a standard SENTRON catalog item, widely specified in industrial and mechanical engineering panels.

MPN