Skip to main content
Siemens 5SY8640-7 — Miniature Circuit Breakers (MCB)

Siemens 5SY8640-7 SENTRON MCB, 4P C-40A 25kA IEC

MPN5SY8640-7
Active

Siemens SENTRON, miniature circuit breaker, 5SY8640-7, 4-pole C-curve 40 A, 25 kA IEC 60947-2, 400 V AC, 4 MW units, IP20.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY8640-7 — Ratings
ParameterValue
Overvoltage categoryIII
5SY8640-7 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

40 A C-curve MCB, 4-pole, 25 kA — SENTRON 5SY8640-7

It carries a 25 kA breaking capacity per IEC 60947-2 at 400 V AC, with a 15 kA DC rating and 5 kA per UL 1077/CSA 22.2 No.235 — so it handles both IEC and North American fault-current requirements on the same device. At 40 A it covers sub-distribution, lighting panels, and general branch circuits in industrial and commercial panels.

Breaking capacity — IEC, UL, and DC

Three breaking-capacity ratings cover the common installation regimes: 25 kA at 400 V AC per IEC 60947-2 (the main specification for industrial MCBs in Europe and Asia), 15 kA at 72 V DC for DC-side protection, and 5 kA per UL 1077 / CSA 22.2 No.235 for North American supplementary protection. That 25 kA IEC figure means it can be used at the service entrance of most industrial sub-distribution boards without an upstream current-limiting fuse.

Snap-on fastening with any mounting position. Combined top and bottom terminals simplify daisy-chaining busbars. Sealable and touch-protected per the product feature. Halogen-free and silicon-free construction suits clean-room or sensitive-environment panels. Neutral conductor switching is integrated (3P+N), so the neutral pole opens and closes with the phases — no separate neutral disconnect required. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz.

Frequently asked questions

How do I get current pricing and availability for 5SY8640-7?

Submit an RFQ through the storefront. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is 5SY8640-7's listed depth on this component line?

The 5SY8640-7 has a depth of 76 mm and an installation depth of 70 mm.

What compliance documentation does this brand provide for 5SY8640-7?

The 5SY8640-7 carries IEC 60947-2, UL 1077, and CSA C22.2 No.235 ratings. It is halogen-free and silicon-free, with IP20 protection when conductors are connected. Specific RoHS/REACH declarations are available from the manufacturer upon request.

Will 5SY8640-7 drop into a panel specified around 5SY4301-7CV without rewiring?

Both are 4-pole SENTRON MCBs on a 4 MW DIN-rail footprint, so the mechanical fit is the same. However, the 5SY8640-7 is a 40 A C-curve rated 25 kA IEC, while the 5SY4301-7CV is a different rating — verify the load current and breaking capacity requirements before swapping. The terminal arrangement and busbar compatibility are identical.

MPN
5SY8640-7