Skip to main content
Siemens 6AG1124-0GC13-2AM0 — HMI Operator Interfaces

Siemens 6AG1124-0GC13-2AM0 7" HMI, -30-70°C, IRT

MPN6AG1124-0GC13-2AM0
Active

Siemens 6AG1124-0GC13-2AM0 7" Comfort Panel, IRT, MPI, CSS, CSV, DCP, MODBUS, TCP/IP, -30 to 70 °C.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6AG1124-0GC13-2AM0 — Display
ParameterValue
Screen diagonal (size)7 in
Display designTFT, bonded, daylight-readable
Touch screenYes; analog, resistive
Number of display colors16 777 216
Backlight MTBF (at 25 °C)50 000 h
6AG1124-0GC13-2AM0 — Communication & I/O
ParameterValue
Alphanumeric keyboardYes; Onscreen keyboard
6AG1124-0GC13-2AM0 — Electrical
ParameterValue
Current consumption (rated)0.7 A
Rated value (DC)24 V
Type of supply voltageDC; operation only with current-compensated reactors (2 x 82 mH) in the umbilical cables as close as possible to the supply terminals
Permissible range, upper limit (DC)28 V
Permissible range, lower limit (DC)19.2 V
6AG1124-0GC13-2AM0 — Mechanical
ParameterValue
Mounting cutout height141 mm
Mounting cutout width197 mm
Portrait mounting possibleYes
Overall depth67 mm
Front panel height158 mm
Front panel width214 mm
Weight (without packaging)1.5 kg
6AG1124-0GC13-2AM0 — Environmental
ParameterValue
Ingress protection, frontIP66
Ingress protection, rearIP20
Max.70 °C
Min.-30 °C

Product details

What this panel is

The 6AG1124-0GC13-2AM0 is a Siemens 7" Comfort Panel equivalent — power, quantity structure, and performance match a standard 7" Comfort Panel, as noted in the listing. This means it fits into the same panel cutout and electrical design as a standard SIMATIC HMI Comfort unit. Rated for -30 °C to 70 °C ambient, it handles enclosures in unheated warehouses, cold storage, or rooftop cabinets without derating concerns at the low end. Protocol support includes IRT (isochronous real-time), MPI, CSS, CSV, DCP, LLDP, SNMP, DHCP, HTTP, HTML, MODBUS, and TCP/IP — meaning it talks natively on PROFINET IRT networks and can also act as a Modbus TCP client or server for legacy SCADA drops. It does not wire CAN or XML, so those connections need a gateway card.

Frequently asked questions

What is the temperature range for this panel?

The 6AG1124-0GC13-2AM0 is rated for -30 °C to 70 °C ambient operating temperature.

Does this panel support CAN bus?

No, CAN is listed as not supported. For CAN connectivity an external gateway module would be needed.

MPN
6AG1124-0GC13-2AM0