Siemens 6AG1134-4GD00-2AB0 — PLCs (Programmable Logic Controllers)

Siemens 6AG1134-4GD00-2AB0 SIPLUS AI 4xI 4-20mA, -25..70°C

MPN6AG1134-4GD00-2AB0

Siemens SIPLUS ET 200SP 6AG1134-4GD00-2AB0 analog input module, 4 AI 4-20 mA, 24 V from power module, -25…70 °C, 7 byte address space.

$290.83Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6AG1134-4GD00-2AB0 — Electrical
ParameterValue
Rated value (DC)24 V; From power module
Power loss (typ.)0.6 W
6AG1134-4GD00-2AB0 — Environmental
ParameterValue
Installation altitude, max.5 000 m
Temperature, min.-25 °C; = Tmin
Temperature, max.70 °C; = Tmax
Ambient temperature vs. altitude/pressure deratingTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
6AG1134-4GD00-2AB0 — Mechanical
ParameterValue
Width15 mm
Height81 mm
Depth52 mm
Weight (approx.)40 g

Product details

The Siemens 6AG1134-4GD00-2AB0 is a SIPLUS variant of the ET 200SP analog input module with 4 channels for 4-20 mA signals, rated for extended ambient temperatures from -25 °C to 70 °C, and carrying current lifecycle status for OEM and MRO sourcing. It accepts 4-20 mA into 25 Ohm burden, integrates over programmable time windows (16,67 or 20 ms), and has a max cycle time of 33–40 ms across all channels.

The -25 °C to 70 °C range is the SIPLUS differentiator versus the standard ET 200SP AI (0–60 °C). If your panel lives in a refrigerated warehouse, freezer tunnel, or outdoor cabinet in a cold climate, this module avoids derating. The 4-20 mA signal into 25 Ohm means the loop power supply must provide sufficient voltage above the module's burden. Most 2-wire transmitters can handle that, but verify compliance voltage for long cable runs. Short-circuit proof at approx. 200 mA per module: if a field wire shorts to ground, the module limits current and reports the fault via group error SF (red LED). It does not isolate between channels, so a single short can disrupt all four inputs unless your wiring separates the loops. Wire-break detection is active only in the 1–5 V measuring range (remark: yes, but for 4-20 mA the break is implied by going below 4 mA – the module flags that as overflow/underflow, not a separate break alarm). Keep that in mind when configuring the input range in your PLC hardware config.

Integrator notes: mounting and wiring

Shielded cable runs up to 200 m are approved; connect the shield at the module side only (no shield on the field end) to avoid ground loops. The internal filter is integrating, so fast transients couple partly through – use twisted-pair cable in high-EMI environments. Isochronous mode is not supported (= No). If your controller demands deterministic cyclic data with zero jitter, this module is not for that use case.

Sourcing reality: active, orderable, region-agnostic

No functional second-source exists: the listed peer MPNs (6ES7136-6AB00-0CA1, 6AG1212-1AE40-2XB0, 6AG1212-1AE40-4XB0) are not analog input modules but other S7 family products. You cannot drop this into a slot meant for a standard ET 200SP AO or CPU without rewiring and reconfiguration. Compliance: CE marked. Isolation tested at 500 V DC. RoHS/REACH/UL are not explicitly in the listed specs – your compliance team should request the Siemens Certificate of Compliance with the RFQ if needed.