Siemens 6AG1134-6PA00-7BD0 S7-1200 Analog Input, 58 mm depth

MPN6AG1134-6PA00-7BD0

Siemens SIPLUS S7-1200 analog input module, 6AG1134-6PA00-7BD0, 58 mm depth, 20 mm width, 100-240 VAC, ±1% accuracy on power, current, voltage.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6AG1134-6PA00-7BD0 — Environmental
ParameterValue
Installation altitude, max.3 000 m
Operating temperature, min. (horizontal mounting)-40 °C; = Tmin; < -25 °C min. permissible supply voltage 110 V AC
Operating temperature, max. (horizontal mounting)70 °C; = Tmax; > +60 °C max. permissible current 1 A per phase
Ambient temperature vs. altitude/pressure deratingTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... Tmax -5K) at 795 hPa ... 701 hPa (+2 000 m ... +3 000 m)
6AG1134-6PA00-7BD0 — Mechanical
ParameterValue
Width20 mm
Height73 mm
Depth58 mm
Weight (approx.)45 g

Product details

Siemens 6AG1134-6PA00-7BD0 is a SIPLUS S7-1200 analog input module dedicated to electrical energy measurement — voltage, current, frequency, active and reactive power, all with ±1% accuracy. It's the module for submetering or power-quality monitoring inside a SIMATIC rack. Power for the module comes directly from the voltage measurement channel L1, so no separate 24 VDC supply is needed — just the 100-240 VAC line being measured. That simplifies wiring in retrofit panels.

Width is 20 mm, depth 58 mm — it takes one base unit slot (BU type D0). Horizontal mounting (standard) lets the module run up to 70 °C ambient; above 60 °C, limit load current to 1 A per phase. Vertical installation caps at 50 °C. Cold start from -40 °C is fine, but below -25 °C the supply voltage must be at least 110 V AC.

What you get out of it

Parameter length per module is 44 bytes (32 input, 12 output). Supports cyclic and acyclic measurement, diagnostic and channel alarms. I&M data included. No isochronous mode — this is for monitoring, not motion control. One thing to note: zero-point suppression is set at 50 mA, meaning currents below that threshold are reported as zero — fine for submetering but if you need to log micro-loads, account for that floor. Voltage measurement handles sinusoidal or distorted waveforms from 45 to 65 Hz. Accuracy for power, current, and voltage is ±1.0%.

Frequently asked questions

What temperature range does it support in horizontal mounting?

Rated -40 °C to 70 °C horizontal, but above 60 °C the per-phase current is limited to 1 A.

Does it need a separate power supply?

No, it's powered through the L1 voltage measurement channel at 100-240 VAC.