Siemens 6AG1138-4FB04-2AB0 — PLCs (Programmable Logic Controllers)

Siemens 6AG1138-4FB04-2AB0 SIPLUS ET 200S F-DQ, SIL 3, 4 DO

MPN6AG1138-4FB04-2AB0

Siemens SIPLUS ET 200S, F-DQ safety output module, 4 digital transistor outputs, 24 V DC, SIL 3 / Cat. 4, rated -25 to 60 °C, 4 A per channel.

$562.61Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

6AG1138-4FB04-2AB0 — I/O
ParameterValue
Digital outputs4
6AG1138-4FB04-2AB0 — Electrical
ParameterValue
Rated value (DC)24 V
Power loss (typ.)3.5 W
Short-circuit protectionYes
6AG1138-4FB04-2AB0 — Environmental
ParameterValue
Installation altitude, max.2 000 m
Temperature, min.-25 °C
Temperature, max.60 °C
Ambient temperature vs. altitude/pressure deratingTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
6AG1138-4FB04-2AB0 — Mechanical
ParameterValue
Width30 mm
Height81 mm
Depth52 mm
Weight (approx.)85 g

Product details

Safety output module for harsh environments

The Siemens 6AG1138-4FB04-2AB0 is a SIPLUS variant of the ET 200S F-DQ safety output module, built to survive the same crusher vibration and abrasive dust that kills standard electronics. It carries SIL 3 per IEC 61508 and Category 4 per EN 954-1, so it is rated for safety functions that demand fault-tolerant shutdown — think emergency-stop circuits, guard-door monitoring, or press-brake control in a mill. Four transistor outputs, each rated 4 A up to 40 °C and 5 A up to 55 °C, with a module total of 6 A max. That means you can drive contactors or solenoid valves directly without an interposing relay, as long as the load current per channel stays inside the thermal limit.

Wiring and fault detection in the panel

Snaps onto the ET 200S DIN-rail profile — the 30 mm width leaves room for adjacent I/O slices in a crowded enclosure. Wiring is screw terminal; the 24 V DC load supply feeds the module separately from the backplane bus, which draws 28 mA max at 3.3 V DC. Built-in wire-break detection (lower limit 12 Ω, upper limit 1 kΩ) and short-circuit detection let the module flag a failed field connection before the safety function is compromised. The group error SF (red LED) pulls the diagnostics bus — the PLC sees the fault without scanning each channel.

Thermal limits and cable runs

The output current derates at the high end: 4 A at 60 °C, same as at 40 °C, but the 55 °C point allows 5 A — so if the cabinet runs hot but stays under 55 °C, you get the extra amp per channel. Cable runs up to 500 m shielded or unshielded — long enough to reach field actuators across a conveyor line or a processing floor. Typical power loss is 3.5 W, manageable without forced cooling in a standard IP20 cabinet.

Frequently asked questions

Is 6AG1138-4FB04-2AB0 compatible with standard ET 200S modules?

Yes — it fits the same ET 200S DIN-rail backplane and communicates over the same backplane bus. It can be mixed with standard I/O slices in the same station, provided the safety CPU handles the F-DQ addressing.

Can 6AG1138-4FB04-2AB0 be used as a replacement for a standard ET 200S F-DQ module?

Yes — it is a direct form-fit-function replacement for the standard F-DQ module in the same slot, with the wider temperature range. No wiring or configuration changes are needed.

What is the maximum cable length for 6AG1138-4FB04-2AB0?

500 m for both shielded and unshielded cable. That covers most field wiring runs in a plant without needing repeaters.