Drive selection memo – 6AG1210-1PE26-2UL0
FSD 30 kW variant outputs 90 A continuous, 41.6 kVA apparent power, IE2 class, efficiency 0.98, power loss 0.765 kW. Braking includes DC braking and integrated brake chopper.
Integration checklist — field service angle
Mount the drive with clearance for top and bottom air intake/exhaust; internal air cooling relies on unobstructed vertical flow. Condensation is not permissible (rated for non-condensing environments), so avoid mounting in unheated enclosures without climate control. Pulse frequency is 4 kHz — derate output current if you raise it. Parameter locking and overload protection are built in; stall protection and blocked-rotor protection are present. Ground-fault, short-circuit, undervoltage, and overvoltage protection are all integrated.