Siemens 6AG1215-1AG31-2XB0 — PLCs (Programmable Logic Controllers)

Siemens 6AG1215-1AG31-2XB0 S7-1200 CPU, -40 to 70°C

MPN6AG1215-1AG31-2XB0

Siemens SIPLUS S7-1200 CPU, 6AG1215-1AG31-2XB0, with extended -40 to 70°C range, PROFINET interface, 4 MB integrated memory, supports FBD, LAD, SCL.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6AG1215-1AG31-2XB0 — I/O
ParameterValue
Digital inputs14; Integrated
Digital outputs10
Input data area1 024 byte
Output data area1 024 byte
6AG1215-1AG31-2XB0 — Processor & Memory
ParameterValue
Execution time, bit operations (typ.)0.085 µs; / instruction
Execution time, word operations (typ.)1.7 µs; / instruction
Execution time, floating-point arithmetic (typ.)2.5 µs; / instruction
Size, max.8 kbyte; Size of bit memory address area
6AG1215-1AG31-2XB0 — Programming
ParameterValue
Programming language: FBDYes
Programming language: LADYes
Programming language: SCLYes
6AG1215-1AG31-2XB0 — Electrical
ParameterValue
Rated value (DC)24 V
Current consumption (rated)500 mA; Typical
Permissible range, lower limit (DC)5 V
Permissible range, upper limit (DC)250 V
Power loss (typ.)12 W
Short-circuit protectionNo; to be provided externally
6AG1215-1AG31-2XB0 — Environmental
ParameterValue
Installation altitude, max.5 000 m
Temperature, min.-40 °C
Temperature, max.70 °C
Operating temperature, min. (horizontal mounting)-40 °C; = Tmin (incl. condensation/frost); start-up @ -25 °C
Operating temperature, max. (horizontal mounting)70 °C; = Tmax; > +60 °C Number of simultaneously controllable inputs and outputs max. 50 %; no signal board can be used
Ambient temperature vs. altitude/pressure deratingTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
6AG1215-1AG31-2XB0 — Mechanical
ParameterValue
Width130 mm
Height100 mm
Depth75 mm
Weight (approx.)520 g
6AG1215-1AG31-2XB0 — Communication
ParameterValue
Interface typePROFINET

Product details

That range covers platform topsides, arctic-term pipelines, and desert-process skids without requiring additional climate control. It shares the standard 130 mm × 100 mm × 75 mm footprint, so it drops into a standard S7-1200 panel without rewiring.

Compared to the later-order-code peer 6AG1215-1AG40-4XB0, this -AG31-2XB0 shares the same temperature rating and communication hardware. The difference lies in firmware version and possibly fieldbus software options. If your application does not require the latest firmware feature set (e.g., extended security functions), this unit is a direct drop-in replacement.

Frequently asked questions

What programming languages does 6AG1215-1AG31-2XB0 support?

It supports FBD, LAD, and SCL as listed in the specification.

What is the operating temperature range?

The CPU operates from -40 °C to +70 °C ambient.

Does it have PROFINET and MODBUS?

Yes, PROFINET (as client and server) and MODBUS TCP/UDP are included.

How much memory does it have?

It has 4 Mbyte integrated work memory.

Can I replace 6AG1215-1AG40-4XB0 with this unit?

The -AG31-2XB0 and -AG40-4XB0 share the same form factor, temperature range, and communication interfaces. The -AG40-4XB0 is a later firmware revision; confirm your application software compatibility before swapping.

MPN