Siemens 6AG1215-1AG40-5XB0 — PLCs (Programmable Logic Controllers)

Siemens 6AG1215-1AG40-5XB0 S7-1200 CPU, -40 to 70°C

MPN6AG1215-1AG40-5XB0
Active

Siemens SIMATIC S7-1200 (SIPLUS variant), 6AG1215-1AG40-5XB0, CPU with FBD/LAD/SCL, -40 to 70°C, PROFINET, 4MB memory.

$679.45 – $1,812.10Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6AG1215-1AG40-5XB0 — I/O
ParameterValue
Digital inputs14; Integrated
Digital outputs10
Input data area1 024 byte
Output data area1 024 byte
6AG1215-1AG40-5XB0 — Processor & Memory
ParameterValue
Execution time, bit operations (typ.)0.085 µs; / instruction
Execution time, word operations (typ.)1.5 µs; / instruction
Execution time, floating-point arithmetic (typ.)2.5 µs; / instruction
Size, max.8 kbyte; Size of bit memory address area
6AG1215-1AG40-5XB0 — Programming
ParameterValue
Programming language: FBDYes
Programming language: LADYes
Programming language: SCLYes
6AG1215-1AG40-5XB0 — Electrical
ParameterValue
Rated value (DC)24 V
Current consumption (rated)500 mA; CPU only
Permissible range, lower limit (DC)5 V
Permissible range, upper limit (DC)250 V
Power loss (typ.)12 W
6AG1215-1AG40-5XB0 — Environmental
ParameterValue
Installation altitude, max.5 000 m
Temperature, min.-40 °C
Temperature, max.70 °C
Ambient temperature vs. altitude/pressure deratingTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
6AG1215-1AG40-5XB0 — Mechanical
ParameterValue
Width130 mm
Height100 mm
Depth75 mm
Weight (approx.)500 g
6AG1215-1AG40-5XB0 — Communication
ParameterValue
Interface typePROFINET

Product details

What this CPU delivers in harsh environments

The 6AG1215-1AG40-5XB0: Programming in FBD, LAD, or SCL means no re-engineering if your existing codebase uses any of those languages — the same TIA Portal project can target this variant directly. Communication covers PROFINET (with shared device support for multi-controller setups), MODBUS TCP, UDP, and PROFIBUS via the CM 1243-5 module. The CPU acts as both MODBUS client and server, which simplifies integration with drives, HMIs, or third-party systems. Analog inputs accept 0–10 V and 0–20 mA signals; these are isolated from the CPU supply, so a ground loop on a temperature transmitter won't couple noise into the logic side.

Panel mounting and power

Footprint is 130 mm wide, 100 mm high, 75 mm deep. Direct rail mount. Integrated 4 Mbyte memory holds code and data; watchdog time, retentive data backup, and real-time clock ride through a 480-hour typical backup battery interval.

Signal integrity notes for analog channels

The isolated input stage means field-signal ground and CPU ground can float relative to each other — a common scenario when the transmitter is on a separate DC rail. No floating ground loops, no common-mode noise on the 0–20 mA loop. Input forcing is available for commissioning: you can override the field reading and simulate a value to test downstream logic without crawling to the sensor.

Sourcing this exact variant

This is the SIPLUS extended-temperature version.

Frequently asked questions

Does it support PROFINET and MODBUS?

Yes. PROFINET interface with shared device capability; MODBUS TCP and UDP both supported. For PROFIBUS, an external CM 1243-5 module is required.

What is the memory capacity?

4 Mbyte integrated memory for code and data. Retentive data backup time is 480 hours typical.

MPN
6AG1215-1AG40-5XB0