Siemens S7-1200 digital output module, 6AG1222-1HF30-2XB0, 8 relay outputs isolated in groups of 2, 2 A per channel, 5-250 V AC / 5-30 V DC, -40 to 70 °C.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

6AG1222-1HF30-2XB0 — Outputs
ParameterValue
Digital outputs8
6AG1222-1HF30-2XB0 — Electrical
ParameterValue
Rated value (DC)5 V DC to 30 V DC
Output current, resistive load, max.2 A
Output current, max. per circuit / per module2 A
Permissible range, upper limit (DC)28.8 V
Permissible range, lower limit (DC)20.4 V
Current consumption from backplane bus (5 V DC), max.120 mA
Power dissipation (typ.)4.5 W
Isolation between channelsRelays
Isolation between channels and backplane bus1 500 V AC for 1 minute
Isolation, channels in groups of2
6AG1222-1HF30-2XB0 — Protection & Diagnostics
ParameterValue
Short-circuit protectionNo; to be provided externally
Diagnostics functionYes
Diagnostic alarmYes
6AG1222-1HF30-2XB0 — Performance
ParameterValue
Output switching delay 0 to 1, max.10 ms
Output switching delay 1 to 0, max.10 ms
Switching frequency, inductive load, max.2 A
Switching frequency, lamp load, max.30 W with DC, 200 W with AC
6AG1222-1HF30-2XB0 — Mechanical & Connection
ParameterValue
Cable length, unshielded, max.150 m
Cable length, shielded, max.500 m
Width45 mm
Height100 mm
Depth75 mm
Weight (approx.)190 g

Product details

The 6AG1222-1HF30-2XB0: The module uses the standard S7-1200 form factor: 45 mm wide, 100 mm high, 75 mm deep. It requires a separately ordered front connector – match it to the screw or spring-cage type your wiring standard calls for. Short-circuit protection is not built in; you must provide external fusing or a circuit breaker per channel or group. The relay coil draws 11 mA from the 24 V load supply per channel, and 120 mA from the backplane bus at 5 V DC. Typical power loss is 4.5 W. Diagnostic alarm and output status indication are available via the S7-1200 backplane bus.

Frequently asked questions

What are the key ratings?

8 relay outputs, each rated 2 A max at 5-250 V AC or 5-30 V DC. Isolated in groups of 2. Operating ambient -40 to 70 °C. Requires external short-circuit protection and a front connector.

How do I source this part?

The part is active. Submit an RFQ for current lead time and pricing – we source to order.

MPN
6AG1222-1HF30-2XB0