Siemens 6AG1312-5BF04-2AY0 SIPLUS S7-300 CPU, FM 8

MPN6AG1312-5BF04-2AY0

Siemens SIPLUS S7-300 CPU 312 (6AG1312-5BF04-2AY0), firmware FM 8, supports LAD/FBD/SCL/STL/GRAPH/HiGraph, extended temperature range -40 to 70°C, EN 50155 railway compliance.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6AG1312-5BF04-2AY0 — I/O
ParameterValue
Digital inputs10
Digital outputs6
ExpandableNo
Input data area64
Output data area64
6AG1312-5BF04-2AY0 — Processor & Memory
ParameterValue
Execution time, bit operations (typ.)0.1 µs
Execution time, word operations (typ.)0.24 µs
Execution time, floating-point arithmetic (typ.)1.1 µs
Size, max.256 byte
6AG1312-5BF04-2AY0 — Programming
ParameterValue
Programming language: FBDYes
Programming language: LADYes
Programming language: SCLYes
6AG1312-5BF04-2AY0 — Electrical
ParameterValue
Rated value (DC)24 V
Current consumption (rated)570 mA
Permissible range, lower limit (DC)19.2 V
Permissible range, upper limit (DC)28.8 V
Power loss (typ.)8 W
Short-circuit protectionYes; Clocked electronically
6AG1312-5BF04-2AY0 — Environmental
ParameterValue
Installation altitude, max.5 000 m
Temperature, min.-40 °C
Temperature, max.70 °C
Ambient temperature vs. altitude/pressure deratingTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)
6AG1312-5BF04-2AY0 — Mechanical
ParameterValue
Width80 mm
Height125 mm
Depth130 mm
Weight (approx.)410 g
6AG1312-5BF04-2AY0 — Communication
ParameterValue
Interface typeIntegrated RS 485 interface

Product details

The CPU occupies the standard S7-300 single-width slot: 80 mm wide, 125 mm high, 130 mm deep. It mounts directly on the DIN rail and interfaces with the backplane bus. No expandability is provided beyond the CPU's built-in I/O channels (64 inputs, 64 outputs). Program upload and monitoring use MPI (RS 485) or PROFIBUS via CP. The module supports forcing of I/O and variables—useful during commissioning when verifying logic against real field wiring.

Frequently asked questions

What firmware version does this CPU run?

This unit runs firmware version FM 8.

Which programming languages does the 6AG1312-5BF04-2AY0 support?

It supports LAD, FBD, SCL, STL, GRAPH, and HiGraph, as well as STEP 7 V5.5+ or V5.3+ with HSP 203.

What is the operating temperature range and railway rating?

It operates from -40 to 70 °C and is EN 50155 compliant (sections 4, 5, 12; T1, Category 1, Class A/B).

Does this CPU have a CE mark?

Yes, CE marking is listed.

MPN