Skip to main content
Siemens 6AG1315-6FF04-2AB0 — PLCs (Programmable Logic Controllers)

Siemens 6AG1315-6FF04-2AB0 S7-300 CPU, -40 to 70°C, ATEX

MPN6AG1315-6FF04-2AB0

Siemens S7-300 CPU, 6AG1315-6FF04-2AB0, SFB type, 8 FM slots, CFC/FBD/LAD/SCL/STL/GRAPH, -40 to 70 °C, ATEX, PROFIsafe, 244 byte inputs/outputs.

$2,369.82Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6AG1315-6FF04-2AB0 — I/O
ParameterValue
Digital inputs0
Digital outputs0
ExpandableNo
Input data area244 byte
Output data area244 byte
6AG1315-6FF04-2AB0 — Processor & Memory
ParameterValue
Execution time, bit operations (typ.)0.05 µs
Execution time, word operations (typ.)0.09 µs
Execution time, floating-point arithmetic (typ.)0.45 µs
Size, max.2 048 byte
6AG1315-6FF04-2AB0 — Programming
ParameterValue
Programming language: FBDYes
Programming language: LADYes
Programming language: SCLYes
6AG1315-6FF04-2AB0 — Electrical
ParameterValue
Rated value (DC)24 V
Current consumption (rated)850 mA
Permissible range, lower limit (DC)19.2 V
Permissible range, upper limit (DC)28.8 V
Power loss (typ.)4.5 W
6AG1315-6FF04-2AB0 — Environmental
ParameterValue
Installation altitude, max.2 000 m
Temperature, min.-40 °C
Temperature, max.70 °C
Ambient temperature vs. altitude/pressure deratingTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
6AG1315-6FF04-2AB0 — Mechanical
ParameterValue
Width40 mm
Height125 mm
Depth130 mm
Weight (approx.)290 g
6AG1315-6FF04-2AB0 — Communication
ParameterValue
Interface typeIntegrated RS 485 interface

Product details

This CPU carries a CE mark and is compliant for ATEX areas. No official lifecycle status is published in this listing, so it is sourced as an active Siemens catalog item. The latest GSD file for PROFIBUS integration is hosted on Siemens’ website.

Panel fit and DIN-rail notes

Width 40 mm, height 125 mm, depth 130 mm. Fits standard S7-300 DIN-rail mounting. RS 485 interface is present; MPI is not on board. PROFIsafe routing works only with an active interface. Forcing is supported. Retentive data must be restarted at each restart.

Frequently asked questions

What is the operating temperature range of the 6AG1315-6FF04-2AB0?

-40 °C to 70 °C.

Is this CPU approved for use in explosive atmospheres?

Yes, it is ATEX certified.

What programming languages does it support?

LAD, FBD, SCL, STL, GRAPH, HiGraph®, and CFC.

Does it support PROFIsafe safety communication?

Yes, PROFIsafe is supported.

MPN
6AG1315-6FF04-2AB0