6AG1331-6SB00-7AY0 - Siemens
MPN6AG1331-6SB00-7AY0
Active
SIPLUS LOGO! power 24 V 1.3 A based on 6EP3331-6SB00-0AY0 with conformal coating, -40…+70 °C, start up -25 °C, stabilized power supply input: 100-240 V AC output: 24 V DC/ 1.3 A
$148.59 – $348.37Ref. price · indicative, final on quote
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jun 2026
Specifications
| Parameter | Value |
|---|---|
| Fuse protection type | internal |
| Type of electrical connection | screw-type terminals |
| Type of output voltage setting | via potentiometer |
| Type of the power supply network | 1-phase AC or DC |
| Voltage curve at output | Controlled, isolated DC voltage |
| Adjustable output voltage | 22.2 ... 26.4 V |
| At rated input voltage 120 | 0.7 A |
| At rated input voltage 230 | 0.35 A |
| Output voltage at DC rated value | 24 V |
| On slow fluctuation of input voltage | 0.1 % |
| Relative overall tolerance of the voltage | 3 % |
| Product function output voltage adjustable | Yes |
All specifications+63 ▾
| Parameter | Value |
|---|---|
| Behavior of the output voltage when switching on | No overshoot of Vout (soft start) |
| At rated output voltage for rated value of the output current typical | 5 W |
| Relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical | 0.2 % |
| Design of Short-Circuit protection | Constant current characteristic |
| Measuring point for output current | 50 mV =^ 1.3 A |
| Property of the output Short-Circuit proof | Yes |
| Current limitation of inrush current at 25 °C maximum | 25 A |
| Buffering time for rated value of the output current in the event of power failure minimum | 40 ms |
| Supplied active power typical | 31.2 W |
| Number of Parallel-Switched equipment resources for increasing the power | 2 |
| Line frequency | 47 ... 63 Hz |
| Depth of the enclosure | 53 mm |
| Width of the enclosure | 36 mm |
| Height of the enclosure | 90 mm |
| Product feature of the enclosure housing can be lined up | Yes |
| In horizontal mounting position during operation | -40; Startup @ -25 °C ... +70 °C; with natural convection |
| Installation altitude at height above sea level maximum | 6 000 m |
| Ambient condition relating to ambient temperature - air pressure - installation altitude | In case of operation at altitudes of 2000 - 6000 m above sea level: Output power derating of -7.5 %/1000 m or reduction of the ambient temperature by 5 K/1000 m |
| MTBF at 40 °C | 3 094 996 h |
| CE marking | Yes |
| Top | 20 mm |
| Left | 0 mm |
| Right | 0 mm |
| At DC | 110 ... 300 V |
| Bottom | 20 mm |
| Typical | 1.7 A |
| At input | L, N: 1 screw terminal each for 0.5 ... 2.5 mm2 single-core/finely stranded |
| At output | +, -: 2 screw terminals each for 0.5 ... 2.5 mm² |
| Rated range | 0 ... 1.3 A; +55 ... +70 °C: Derating 2%/K |
| Rated value | 1.3 A |
| 1 rated value | 50 Hz |
| 2 rated value | 60 Hz |
| In the feeder | Recommended miniature circuit breaker: from 6 A characteristic B or from 2 A characteristic C |
| Initial value | 85 V |
| Mounting | Snaps onto DIN rail EN 60715 35x7.5/15, direct mounting in different mounting positions |
| Full-Scale value | 264 V |
| I2t value maximum | 0.8 A²·s |
| Other information | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) |
| Galvanic isolation | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 |
| Maximum rated value | 240 V |
| Minimum rated value | 100 V |
| Protection class IP | IP20 |
| Bridging of equipment | Yes |
| Efficiency in percent | 86 % |
| Response delay maximum | 0.5 s |
| For emitted interference | EN 55022 Class B |
| For interference immunity | EN 61000-6-2 |
| Load step 10 to 90% typical | 1 ms |
| Load step 90 to 10% typical | 1 ms |
| During storage and transport | -40 ... +85 °C |
| At output 1 at DC rated value | 24 V |
| Design of input wide range input | Yes |
| During NO-Load operation maximum | 0.3 W |
| On slow fluctuation of ohm loading | 0.1 % |
| Operating resource protection class | Class II (without protective conductor) |
| Design of the overvoltage protection | Yes, according to EN 60950-1 |
| Display version for normal operation | Green LED for output voltage OK |
| Operating condition of the mains buffering | at Vin = 187 V |
| Galvanic isolation between input and output | Yes |
| Overcurrent overload capability when switching on | 150% Iout rated typ. 200 ms |
| Overcurrent overload capability in normal operation | overload capability 150% Iout rated typ. 200 ms |
| Chemical resistance to commercially available cooling lubricants | Yes; incl. diesel and oil droplets in the air |
| Product conformity of the coating qualification and performance of electrical insulating compound for printed board assemblies according to IPC-CC-830A | Yes; Conformal Coating, Class A |
MPN
6AG1331-6SB00-7AY0