Skip to main content
Siemens 6AG1331-7KB02-2AB0 — Analog Input Modules

Siemens 6AG1331-7KB02-2AB0 AI module, -40 to 70 °C

MPN6AG1331-7KB02-2AB0

Siemens SIPLUS 6AG1331-7KB02-2AB0 analog input module, thermocouple and RTD plus voltage/current/resistance, parameterizable, -40 °C to 70 °C, UL/CE/KC marked.

$300.99 – $893.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6AG1331-7KB02-2AB0 — Inputs & Signal Ranges
ParameterValue
Number of analog inputs2
Current input rangeYes
Voltage input rangeYes
Resistance measuring rangesYes
RTD support (resistance thermometer)Yes
Thermocouple support (types)Yes
Input range: 0 to 20 mAYes
Input range: 4 to 20 mAYes
Input range: -10 to +10 VYes
Input range: -5 to +5 VYes
Input range: -80 to +80 mVYes
Input range: 0 to 600 OhmYes
RTD type: Pt100Yes
Current measurement: 2-wire transducerYes
Current measurement: 4-wire transducerYes
Input resistance (0 to 20 mA)25 Ω
Input resistance (4 to 20 mA)25 Ω
Input resistance (-10 to +10 V)100 kΩ
Permissible input voltage, max. (destruction limit)20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)
Permissible input current, max. (destruction limit)40 mA
Max. shielded signal cable length200 m; 50 m at 80 mV and thermocouples
6AG1331-7KB02-2AB0 — Measurement Performance
ParameterValue
Resolution (bit incl. sign), max.15 bit; Unipolar: 9/12/12/14 bit; bipolar: 9 bit + sign/12 bit + sign/12 bit + sign/14 bit + sign
Voltage measurement error (±)0.6 %; ±0.6% (80 mV, 2.5 V to 10 V); ±0.4% (250 mV to 1 000 mV)
Current measurement error (±)0.5 %; 3.2 to 20 mA
Interference voltage suppression (at interference frequency)400 / 60 / 50 / 10 Hz
6AG1331-7KB02-2AB0 — Diagnostics & Monitoring
ParameterValue
Diagnostic alarmYes
Diagnostics functionYes; Parameterizable
Limit value alarmYes; Parameterizable, channel 0
6AG1331-7KB02-2AB0 — Isolation
ParameterValue
Isolation: channels to backplane busYes
Isolation: between channelsNo
Isolation test voltage500 V DC
6AG1331-7KB02-2AB0 — Power
ParameterValue
Rated value (DC)24 V
Power loss, typ.1.3 W
Reverse polarity protectionYes
6AG1331-7KB02-2AB0 — Mechanical
ParameterValue
Required front connector20-pin
Width40 mm
Height125 mm
Depth120 mm
Weight, approx.250 g

Product details

What lands on the DIN rail

The Siemens 6AG1331-7KB02-2AB0 is an analog input module that accepts thermocouples, the common RTD types — Pt 100 and Ni 100 — and a broad set of voltage, current and resistance ranges. One parameterizable module covers thermocouples, resistance thermometers and standard process signals, which is what makes it a sensible single-line BOM entry for a mixed sensor panel rather than a dedicated card per signal type. The module carries a CE mark, a KC approval and a UL listing under file E239877, so it is documented for North American, European and Korean panel builds.

What it will and will not read

The supported thermocouple list is B, E, J, K, N; R, S, T, L and U are not on the supported list, so a Type K or Type J probe is the safe default and a Type T low-temperature bath probe needs a different module. RTD coverage is Pt 100 and Ni 100; Cu 10 is not supported. The module is not specified against the rail vehicle or trackside EMC standards, so those environments need a different variant; the listed industrial compliance is UL/CE/KC only.

Frequently asked questions

What is 6AG1331-7KB02-2AB0's listed max. (70 °C) on this component line?

Maximum operating ambient is 70 °C for the 6AG1331-7KB02-2AB0.

What is 6AG1331-7KB02-2AB0's listed min. (-40 °C) on this component line?

Minimum operating ambient is -40 °C for the 6AG1331-7KB02-2AB0.

MPN
6AG1331-7KB02-2AB0