Skip to main content
Siemens 6AG1334-2BA20-4AA0 — PLC I/O & Expansion Modules

Siemens 6AG1334-2BA20-4AA0 SITOP PSU, 24V 10A

MPN6AG1334-2BA20-4AA0
Active

Siemens SITOP industrial power supply, 6AG1334-2BA20-4AA0, 24V DC adjustable output, 10A rated, 90% efficiency, active production.

$396.24Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6AG1334-2BA20-4AA0 key specifications
ParameterValue
Fuse protection typeT 6.3 A/250 V (not accessible)
Type of signal at outputRelay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK"
Type of electrical connectionscrew-type terminals
Type of output voltage settingvia potentiometer
Type of the power supply network1-phase AC
Voltage curve at outputControlled, isolated DC voltage
Adjustable output voltage22.8 ... 28 V
At rated input voltage 1204.49 A
At rated input voltage 2301.91 A
Output voltage at DC rated value24 V
On slow fluctuation of input voltage0.1 %
Relative overall tolerance of the voltage3 %

All specifications

6AG1334-2BA20-4AA0 additional specifications
ParameterValue
Product function output voltage adjustableYes
Behavior of the output voltage when switching onOvershoot of Vout < 3 %
At rated output voltage for rated value of the output current typical25 W
Relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical0.3 %
At Short-Circuit during operation1 000 ms
Response value current limitation12 ... 14.6 A
Design of Short-Circuit protectionConstant current characteristic
On Short-Circuiting during the Start-Up1 000 ms
At Short-Circuit during operation typical32 A
Property of the output Short-Circuit proofYes
On Short-Circuiting during the Start-Up typical32 A
Current limitation of inrush current at 25 °C maximum60 A
Buffering time for rated value of the output current in the event of power failure minimum20 ms
Supplied active power typical288 W
Number of Parallel-Switched equipment resources for increasing the power2
Line frequency47 ... 63 Hz
Depth of the enclosure120 mm
Width of the enclosure70 mm
Height of the enclosure125 mm
Product feature of the enclosure housing can be lined upYes
In horizontal mounting position during operation-25 ... +70 °C; with natural convection
Installation altitude at height above sea level maximum6 000 m
Ambient condition relating to ambient temperature - air pressure - installation altitudeIn case of operation at altitudes of 2000 - 6000 m above sea level: Output power derating of -7.5 %/1000 m or reduction of the ambient temperature by 5 K/1000 m
MTBF at 40 °C1 614 510 h
CE markingYes
Top50 mm
Left0 mm
Right0 mm
Bottom50 mm
1 at AC85 ... 132 V
2 at AC170 ... 264 V
Typical0.8 mA
At inputL, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm² single-core/finely stranded
At output+, -: 2 screw terminals each for 0.5 ... 2.5 mm²
Rated range0 ... 12 A; 12 A up to +45°C; +60 ... +70 °C: Derating 3%/K
Rated value10 A
1 rated value50 Hz
2 rated value60 Hz
In the feederRecommended miniature circuit breaker: from 10 A characteristic C
Initial valueAutomatic range selection
MountingSnaps onto DIN rail EN 60715 35x7.5/15
I2t value maximum5.6 A²·s
Other informationSpecifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)
Galvanic isolationSafety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178
1 at AC rated value120 V
2 at AC rated value230 V
Protection class IPIP20
Bridging of equipmentYes
Efficiency in percent90 %
Electrical accessoriesBuffer module
For auxiliary contactsAlarm signals: 2 screw terminals for 0.5 ... 2.5 mm²
Response delay maximum0.3 s
For emitted interferenceEN 55022 Class B
For interference immunityEN 61000-6-2
Load step 10 to 90% typical1 ms
Load step 90 to 10% typical1 ms
During storage and transport-40 ... +85 °C
At output 1 at DC rated value24 V
For mains harmonics limitationEN 61000-3-2
Overvoltage overload capability2.3 × Vin rated, 1.3 ms
Design of input wide range inputNo
On slow fluctuation of ohm loading1 %
Operating resource protection classClass I
Design of the overvoltage protectionprotection against overvoltage in case of internal fault Vout < 33 V
Display version for normal operationGreen LED for 24 V OK
Operating condition of the mains bufferingat Vin = 93/187 V
Galvanic isolation between input and outputYes
Overcurrent overload capability in normal operationoverload capability 150 % Iout rated up to 5 s/min
Chemical resistance to commercially available cooling lubricantsYes; incl. diesel and oil droplets in the air
Product conformity of the coating qualification and performance of electrical insulating compound for printed board assemblies according to IPC-CC-830AYes; Conformal Coating, Class A

Product details

Sourcing at a glance

The 6AG1334-2BA20-4AA0: Active current production — no last-time-buy or phase-out to watch. This is a standard SITOP catalog item: 24 V DC output, adjustable 22.8–28 V to compensate for voltage drop on long cabling. Rated 10 A continuous, with headroom to 12 A up to 45 °C; above that, derate 3 %/K to 70 °C. Efficiency hits 90 % at rated load, so panel heat dissipation stays low.

Screw terminals: one each for L, N, PE at line side (0.5–2.5 mm²), two each for + and – at load side (same wire range). Keep 50 mm clearance above and below the enclosure for convective cooling — zero clearance left/right so you can gang units. IP20, so fit in a clean, dry cabinet.

Control and signalling

Automatic range selection — feed it 85–132 V or 170–264 V AC, 47–63 Hz, and it picks the tap. A relay output (NO contact, 60 V DC / 0.3 A) asserts when the 24 V rail is healthy; two alarm signal terminals (screw, 0.5–2.5 mm²) carry that. Response delay on power-up under 0.3 s.

Getting a quote

Standard catalog, active line — no supply chain gymnastics. We quote against your BOM line and factory lead time. Drop an RFQ with quantity and target ship date; we’ll lock allocation from Siemens distribution.

Frequently asked questions

What compliance documentation does this power supply carry?

CE marked, safety extra-low voltage per EN 60950-1 and EN 50178. No UL or other agency marks listed in the spec sheet.

What are the mounting clearances?

Must maintain 50 mm clearance above and below for airflow. Zero clearance left and right — units can be mounted side-by-side. DIN rail mounting per EN 60715.

MPN