Siemens 6AG1344-0SB00-7AY0 Power Supply, 48-54VDC 5A

MPN6AG1344-0SB00-7AY0
Active

Siemens SIPLUS power supply, 6AG1344-0SB00-7AY0, 48-54 VDC adjustable output, 5 A rated, 92% efficiency, DIN rail mounting.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6AG1344-0SB00-7AY0 key specifications
ParameterValue
Fuse protection typeT 6.3 A (not accessible), soldered
Type of signal at outputRelay contact (NO contact, rating 60 V DC/ 0.3 A) for 48 V OK
Type of electrical connectionscrew-type terminals
Type of output voltage settingvia potentiometer; max. 240 W
Type of the power supply network1-phase AC
Voltage curve at outputControlled, isolated DC voltage
Adjustable output voltage48 ... 54 V
At rated input voltage 1204.4 A
At rated input voltage 2302 A
Output voltage at DC rated value48 V
On slow fluctuation of input voltage0.2 %
Relative overall tolerance of the voltage3 %

All specifications

6AG1344-0SB00-7AY0 additional specifications
ParameterValue
Product function output voltage adjustableYes
Behavior of the output voltage when switching onOvershoot of Vout approx. 2 %
At rated output voltage for rated value of the output current typical12 W
Relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical0.3 %
Design of Short-Circuit protectionElectronic shutdown, automatic restart
Property of the output Short-Circuit proofYes
Current limitation of inrush current at 25 °C maximum58 A
Buffering time for rated value of the output current in the event of power failure minimum30 ms
Supplied active power typical240 W
Number of Parallel-Switched equipment resources for increasing the power2
Line frequency47 ... 63 Hz
Depth of the enclosure125 mm
Width of the enclosure42 mm
Height of the enclosure125 mm
Product feature of the enclosure housing can be lined upYes
In horizontal mounting position during operation-40; Startup @ -25 °C ... +70 °C; with natural convection
Installation altitude at height above sea level maximum6 000 m
Ambient condition relating to ambient temperature - air pressure - installation altitudeIn case of operation at altitudes of 2000 - 6000 m above sea level: Output power derating of -7.5 %/1000 m or reduction of the ambient temperature by 5 K/1000 m
MTBF at 40 °C1 050 000 h
CE markingYes
Top50 mm
Left0 mm
Right0 mm
Bottom50 mm
1 at AC85 ... 132 V
2 at AC170 ... 264 V
Typical1 mA
At inputL, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm² single-core/finely stranded
At output+, -: 2 screw terminals each for 0.5 ... 2.5 mm²
Rated range0 ... 5 A; +60 ... +70 °C: Derating 5%/K
Rated value5 A
1 rated value50 Hz
2 rated value60 Hz
In the feederRecommended miniature circuit breaker: from 10 A characteristic C
MountingSnaps onto DIN rail EN 60715 35x7.5/15
I2t value maximum1.5 A²·s
Other informationSpecifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)
Galvanic isolationSafety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178
1 at AC rated value100 V
2 at AC rated value230 V
Protection class IPIP20
Bridging of equipmentYes
Efficiency in percent92 %
For auxiliary contacts13, 14 (alarm signal): 1 screw terminal each for 0.5 ... 2.5 mm²
Response delay maximum1.5 s
For emitted interferenceEN 61000-6-4
For interference immunityEN 61000-6-2
Load step 10 to 90% typical0.5 ms
Load step 90 to 10% typical0.5 ms
During storage and transport-40 ... +85 °C
At output 1 at DC rated value48 V
For mains harmonics limitationEN 61000-3-2
Design of input wide range inputNo
On slow fluctuation of ohm loading0.5 %
Operating resource protection classClass I
Design of the overvoltage protection< 60 V
Display version for normal operationGreen LED for 48 V OK
Operating condition of the mains bufferingat Vin = 120/230 V
Galvanic isolation between input and outputYes
Chemical resistance to commercially available cooling lubricantsYes; incl. diesel and oil droplets in the air
Product conformity of the coating qualification and performance of electrical insulating compound for printed board assemblies according to IPC-CC-830AYes; Conformal Coating, Class A

Product details

Regulated adjustable-output 48 V power supply for automation panels

The Siemens 6AG1344-0SB00-7AY0 is an active-production SIPLUS power supply delivering a controlled, isolated 48-54 VDC at 5 A, with 92% efficiency and a relay alarm output for 48 VOK status. Accepts two AC voltage ranges (85–132 V and 170–264 V) at 47–63 Hz. The auxiliary relay (NO contact, 60 V DC / 0.3 A) signals when the output is within tolerance — useful for remote status monitoring in a control system.

Mounting and thermal derating

Snaps onto 35 mm DIN rail per EN 60715; the 42 mm wide enclosure (125 x 125 mm) clears adjacent modules with no side spacing (0 mm left/right clearance required). Top and bottom need 50 mm free air each for convection. Full 5 A output is available from 0–60 °C; above 60 °C derate by 5 % per Kelvin up to 70 °C. Plan enclosure ventilation to avoid premature derating if mounted near heat sources.

Terminations and protection

Input L-N-PE use single screw terminals (0.5–2.5 mm²); output + and - use double terminals per pole to simplify daisy-chaining to loads. The alarm relay also lands on screw terminals. A non-accessible soldered T 6.3 A fuse protects the supply; the recommended upstream miniature circuit breaker is 10 A characteristic C.

CE marked, IP20 rated, and meets emission standard EN 61000-6-4 and immunity EN 61000-6-2. Galvanic isolation provides SELV output per EN 60950-1 and EN 50178.

Frequently asked questions

What spacing is required around the 6AG1344-0SB00-7AY0 in a panel?

No side clearance is needed (0 mm left and right), but maintain at least 50 mm free space above and below the enclosure for convection cooling.