Skip to main content
Siemens 6AG1407-0KA02-7AA0 — Industrial PCs

Siemens 6AG1407-0KA02-7AA0 SIPLUS S7-400 PS, 20 W, 2 Slots

MPN6AG1407-0KA02-7AA0
Active

Siemens SIPLUS S7-400 power supply, 6AG1407-0KA02-7AA0, PS 407, 20 W typ, 2 slots, -25 to 70 °C with external battery box.

$1,282.70 – $3,525.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

6AG1407-0KA02-7AA0 — Performance
ParameterValue
Required slots2
6AG1407-0KA02-7AA0 — Electrical
ParameterValue
Power loss (typ.)20 W
6AG1407-0KA02-7AA0 — Mechanical
ParameterValue
Width50 mm
Height290 mm
Depth217 mm
Weight (approx.)1 200 g
6AG1407-0KA02-7AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C; using the external battery box SIPLUS 6AG1971-0AA00-7AA0 for buffer mode
Operating temperature, min.-25 °C; using the external battery box SIPLUS 6AG1971-0AA00-7AA0 for buffer mode
Ambient temperature vs. altitude / pressureTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
Installation altitude, max.2 000 m
Conformal coating (IPC-CC-830A)Yes; Conformal coating, Class A
Pollution protection (EN 60664-3)Yes; Type 1 protection
Corrosive-gas conditions (ISA-71.04)Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)

Product details

What it powers and where it fits

The Siemens 6AG1407-0KA02-7AA0 is a SIPLUS S7-400 power supply — the ruggedized version of the standard PS 407, built for extended-temperature and harsh-condition installations. It occupies 2 slots in an S7-400 rack and delivers the 5 V DC backplane bus current (up to 10 A, no base load required) and 24 V DC backplane current (up to 1 A, idling-proof) that the rack and its I/O modules need to run.

Temperature range with the battery box

Without that battery box, the backup battery option is limited to 0 °C to +60 °C using 2× lithium AA cells (3.6 V/2.3 Ah). For the full -25 °C to +70 °C and/or 100 % RH, you need the external battery box and 2× MONO cell design D cells. That makes the battery box a mandatory line item if your site sees sub-zero starts or sustained high humidity.

AC and DC input flexibility

This supply accepts both AC and DC inputs: 120 V AC (0.9 A), 230 V AC (0.5 A), 120 V DC (1 A), and 230 V DC (0.5 A). It handles 50/60 Hz (47 Hz to 63 Hz permissible). The active power input is 95 W typ, with a typical power loss of 20 W. Inrush current hits 63 A max at full width half maximum of 1 ms — factor that into your upstream breaker coordination.

Frequently asked questions

What is the difference between 6AG1407-0KA02-7AA0 and 6ES7407-0KA02-0AA0?

Buyers often need to justify the premium for the SIPLUS version and ensure compatibility.

What is the operating temperature range of 6AG1407-0KA02-7AA0?

The wide temperature range (-25 to +70 °C) is a key selling point for harsh environments.

Where can I buy 6AG1407-0KA02-7AA0 with stock available?

Buyers need to source parts quickly for production or maintenance downtime.

What is the price of 6AG1407-0KA02-7AA0?

Cost is a primary factor for procurement decisions and budget planning.

Is 6AG1407-0KA02-7AA0 a direct replacement for 6ES7407-0KA02-0AA0?

Maintenance techs need to know if swapping to the conformal coated version is drop-in.

What are the output specifications of 6AG1407-0KA02-7AA0?

Design engineers must verify voltage and current ratings for their S7-400 system.

MPN